1.1.4 AbbreviationsAlternating current ACAmerican wire gauge AWGAmpere/AMP AAutomatic Motor Adaptation AMACurrent limit ILIMDegrees Celsius °CDirect current DCDrive Dependent D-TYPEElectro Magnetic Compatibility EMCElectronic Thermal Relay ETRfrequency converter FCGram gHertz HzHorsepower hpKilohertz kHzLocal Control Panel LCPMeter mMillihenry Inductance mHMilliampere mAMillisecond msMinute minMotion Control Tool MCTNanofarad nFNewton Meters NmNominal motor current IM,NNominal motor frequency fM,NNominal motor power PM,NNominal motor voltage UM,NPermanent Magnet motor PM motorProtective Extra Low Voltage PELVPrinted Circuit Board PCBRated Inverter Output Current IINVRevolutions Per Minute RPMRegenerative terminals RegenSecond sec.Synchronous Motor Speed nsTorque limit TLIMVolts VThe maximum output current IVLT,MAXThe rated output current supplied by thefrequency converterIVLT,N1.1.5 Available Literature for VLT® HVACDrive- Design Guide MG.11.Bx.yy entails all technicalinformation about the frequency converter andcustomer design and applications.- Programming Guide MG.11.Cx.yy providesinformation on how to programme and includescomplete parameter descriptions.- Application Note, Temperature Derating Guide,MN.11.Ax.yy- PC-based Configuration Tool MCT 10, MG.10.Ax.yyenables the user to configure the frequencyconverter from a Windows™ based PCenvironment.- Danfoss VLT® Energy Box software atwww.danfoss.com/BusinessAreas/DrivesSolutionsthen choose PC Software Download- Operating Instructions VLT® HVAC Drive BACnet,MG.11.Dx.yy- Operating Instructions VLT® HVAC Drive Metasys,MG.11.Gx.yy- Operating Instructions VLT® HVAC Drive FLN,MG.11.Zx.yyx = Revision numberyy = Language codeDanfoss technical literature is available in print from yourlocal Danfoss Sales Office or online at:www.danfoss.com/BusinessAreas/DrivesSolutions/Documen-tations/Technical+Documentation.htm1.1.6 DefinitionsFrequency converter:IVLT,MAXMaximum output current.IVLT,NRated output current supplied by the frequency converter.UVLT, MAXMaximum output voltage.Input:Control commandStart and stop the connected motor by means of LCP anddigital inputs.Functions are divided into two groups.Functions in group 1 have higher priority than functions ingroup 2.Group 1 Reset, Coasting stop, Reset and Coasting stop,Quick-stop, DC braking, Stop and the [OFF] key.Group 2 Start, Pulse start, Reversing, Start reversing, Jogand Freeze outputMotor:Motor RunningTorque generated on output shaft and speed from zerorpm to max. speed on motor.fJOGMotor frequency when the jog function is activated (viadigital terminals).Introduction VLT® HVAC Drive Programming Guide4 MG.11.CC.02 - VLT® is a registered Danfoss trademark11