CUSTOM CABLE ELECTRICAL CONNECTIONS514INPUT 3 - 4 CONNECTIONS USING EXTERNAL POWEREXTERNAL DEVICEDS6400I3AVextGroundV+ 5V ~~+ -GroundVI4A+ 5V ~~+ -I34BVextFigure 67 - I3/I4 PNP Input Command using External Power4.4.1 Code VerifierIf the DS6400 is used as a Code Verifier, the verifier code can be configured in softwarethrough the Genius™ configuration program. However it is also possible to use one of theinputs to trigger when the scanner should store a code read as the verifier code.The Code Verifier parameter must be enabled, and the configuration parameters to allowcorrect Code Type reading must be saved to the scanner in order to read the verifier code.When the selected input is activated, the next read code will be stored as the verifier code inthe scanner's non-volatile (Flash) memory.For more details see the Verifier Parameters in the "6-8 K Software Configuration ParameterGuide” or Help file.4.5 OUTPUTSThree general purpose outputs are available. The electrical features are given below:Outputs 1 and 2Maximum Voltage 30 VCollector Current (pulse) 130 mA Max.Collector Current (continuous) 40 mA Max.Saturation Voltage (VCE) 1 V at 10 mA Max.Maximum Power Dissipation 90 mW at 50°C (Ambient temperature)