TYPICAL LAYOUTS6777.1.3 Fieldbus NetworksThe Fieldbus models (Ethernet, DeviceNet, or Profibus) offer connectivity without anyconverter or adapter needed.The DS6400 Lonworks master communicates as a Fieldbus slave to a remote host (i.e.remote PC connected via Internet or PLC Fieldbus Master) by means of a cable connectedto the Fieldbus connector provided. It can be activated by a signal generated by the remoteHost or by a physical presence sensor.The external signals (trigger, encoder) are connected to the master through the CBX100.The entire system is powered by the PWR-240 where:Power is distributed through two CAB-63xx cables to avoid excessive current draw.The master is connected to the CBX100 through the CAB-F0x, and provides power to thePS and Encoder.Since the master DS6400 is a Fieldbus model, it is internally terminated. The last slaveDS6400 is terminated with the BT-6000.The master connects directly to the remote host through its Fieldbus interface.* P.S. (Presence Sensor) connected to Input 1 (External Trigger/PS) input.** CBX100 jumper set to accept scanner power.*** Encoder connected to Input 2 (Encoder) input.Figure 87 – Synchronized Network with DS6400 Master and 6K Family Slaves - Fieldbus HostCAB-610xCBX100**Remote HostMasterSlave 1Slave 2Slave 3PWR-240P.S.*CAB-610xCAB-F0xCAB-610x CAB-610xSlave 4CAB-63xx CAB-63xxI/O, AUX, Encoder***BT-6000Fieldbus