References242 Heron™ HD3130Scanning Active TimeThis setting specifies the amount of time that the reader stays in scan ON stateonce the state is entered. The range for this setting is from 1 to 255 seconds in1-second increments.Follow these instructions to set this feature:1. Determine the desired setting.2. Pad the result with leading zeroes to yield three digits. For example: 0 =000, 5 = 005, 20 = 020, etc.3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Program-ming Mode.4. Scan the bar code: SELECT SCANNING ACTIVE TIME SETTING on page 82.5. Scan the appropriate three digits from the keypad in Appendix D, Keypadthat represent the duration which was determined in the steps above. Youwill hear a two-beep indication after the last character.NOTEIf you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start againat the beginning.6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit ProgrammingMode.This completes the procedure. See the table below for examples of how to setthis feature.Table 18. Scanning Active Time Setting ExamplesSTEP ACTION EXAMPLES1 Desired Setting 1 Second 90 Sec. (1.5 min.) 180 Sec. (3 min.) 255 Seconds (4.25min.)2 Pad leading zero(es) 001 090 180 2553 Scan ENTER/EXIT PROGRAMMING MODE4 Scan SELECT SCANNING ACTIVE TIME SETTING5 Scan Three Characters FromAppendix D, Keypad ‘0’, ‘0’ and ‘1’ ‘0’, ‘9’ and ‘0’ ‘1’, ‘8’ and ‘0’ ‘2’, ‘5’ and ‘5’6 Scan ENTER/EXIT PROGRAMMING MODE