4-6 Magellan® 8100/8100Ω and 8200/8200Ω ScannerScale Error ReportingScale diagnostics uses the Remote Scale Display and the Zero Status lampto communicate specific scale failures. The following chart shows theRemote Display messages, the Scale Status lamp indication, the problemthat the scale is experiencing and what action should be taken. Whentroubleshooting, always remember to check all cable connections firstbefore proceeding with other problem isolation steps.Table 4-2. Scale Error ReportingRemoteDisplayScale StatusLampProblemDescription Action RequiredE _1Flash, pause, 1 blink,long pause, repeatsequence.Too much motion at power-up.Check for stable installation. Changescale motion filter using the labelsfound in Section 6; restart. If problempersists, scale may require calibration.E__2Flash, pause, 2blinks, long pause,repeat sequence.Calibration lost. Call technical support personnel. Re-calibrate; restart; recertify (if required).E__3Flash, pause, 3blinks, long pause,repeat sequence.Scale communication lost.Internal scanner/scale prob-lem.Call technical support personnel;report error.E__4Flash, pause, 4blinks, long pause,repeat sequence.Scale module failure. Call technical support personnel;report error.E__5Flash, pause, 5blinks, long pause,repeat sequence.Internal software fault. Call technical support personnel;report error.