Dea 124RR Instructions And Warnings
1 2 4 R RROperating instructions and warnings18Channel selection and linking on the transmitterThe built-in receiver can control both the start input and the pedestrian one. By setting the correct valueof the parameter “P009 Selection and linking of channels” it is possible to decide which key of the tran-smitter will activate each input.If you check on the “working parameters” table you will realize that the P009 parameter allows you tochoose among 16 different combinations. If, for instance, you attribute value “3” to the parameter P009,all memorized transmitters will activate the start input through the CH1 and the pedestrian input throughCH4. Please refer to chapter “8.4 Personalization of working parameters” in order to select your owncombination.8.4 Personalization of working parametersInstructions Function DisplayThe control board is ready to receive instructionsScroll down the parameters until you visualize the one you wish to set (ex. P010)Confirm! The display shows the set parameter valueIncrease or decrease the value until you reach the value you wish to defineConfirm! The display shows again the parameterScroll down the parameters until you visualise “----”. The control board awaitsfurther instructionsThe automation is now ready to work according to the new working parameters.8.5 Resetting of default parameters (p.007)DEA 124RR control board software includes a reset procedure to restore default values (the one set bythe maker) of all settable parameters. The value originally set for each parameter is shown in the “workingparameters table”. In case you should reset all values and restore all default values, proceed as follows:Instructions Function DisplayThe control board is ready to receive instructionsScroll down the parameters until you visualize P007Confirm! The control board awaits a further confirmationConfirm by pressing on the OK button. The procedure startsAll parameters are now set at their original valueScroll down the parameters until you visualise “----”. The control board awaitsfurther instructions8.6 Safety devicesDEA 124RR control board allows fitters to set up installations that truly comply with European regula-tions concerning automated garage doors and gates. More specifically, this control board allows you tocomply with the limits set by the same regulations as to impact forces in case of collision with obstacles.DEA 124RR control board is equipped with a built-in anti-crush safety device that, associated to thepossibility of tuning up the motors’ speed, allows you to comply with the limits imposed by the abovementioned regulations in most installations.In particular, you can adjust the anti-crush safety device sensitivity by properly setting the value assi-gned to the following parameters (see also “8.4 Personalization of working parameters “):•P014 motor 1 force in opening: from 30 (min. force, max sensitivity) to 100 (max force, neutralized sensitivity)•P015 motor 1 force in closing: from 30 (min. force, max sensitivity) to 100 (max force, neutralized sensitivity)In case the gate structural features do not allow you to comply with the above force limits, it is possibleto use external safety devices inputs (terminal no. 12). SIC inputs can be configured by properly settingparameter no. 18:•P018= 0 “rib” mode functioning: when the input is activated the movement direction of the motors is inverted.•P018=1“photoelectric barriers” mode functioning: when the input is activated, the motor stops. |
Related manuals for Dea 124RR
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine