DECATHLON SERIES GAS FRYERS (CE)CHAPTER 7: TROUBLESHOOTING7-27.2 Pilot Burner Malfunction (cont.)4. Check all connections for cleanliness and security.C. Pilot flame of proper size, but is unstable. Flame wavers and does not envelop thethermocouple completely at all times.1. Check for drafts that might be caused by air conditioning equipment or make-up airapparatus. Turn air-moving equipment off and recheck the pilot.7.3 Main Burner MalfunctionsA. Main burner will not come "ON"; gas not detected at main burner.1. Check that the gas valve is open.2. Check that the pilot is ignited and is operating properly.3. Authorized Service Agent Only: Check the high-limit switch for continuity.4. Authorized Service Agent Only: Check the combination gas valve and replace ifdefective.B. Main burner flames are small and appear lazy; shortening does not come up to temperaturequickly.1. Authorized Service Agent Only: Check gas pressure at the pressure tap of the gas valve.Use dial type or standard water-type U-gauge manometer. With burner in operation, thepressure should be 10 mbar (4" W.C.) for natural gas, and 27.5 mbar (11" W.C.) forpropane. If not, remove the pressure regulator adjustment cover. Use screwdriver toturn the adjusting screw for proper pressure. Replace cover, re-check pressure and re-install pressure tap plug.C. Signs of excessive temperature; shortening scorches and quickly becomes discolored.1. Check operating thermostat. May be out of adjustment or calibration. Recalibrate ifnecessary.2. Check gas pressure as outlined above.3. Shortening used is of inferior quality and/or shortening has been used too long. Replaceshortening.4. Ensure frypot is clean when refilling with new shortening.