F-4 Dell PowerEdge 2200 Systems User’s GuideWarning: System fan isnot functioning.The cooling-fan power cableis disconnected, or the cool-ing fan is faulty.Ensure that the fan is connected to the FAN con-nector on the system board. If the problempersists, the fan must be replaced.Resource conflict The BIOS detected aresource conflict while con-figuring a plug and play ISAor PCI expansion card.See “Resolving Resource Conflicts” in Chap-ter 5.Warning: IRQ not ini-tializedThe BIOS detected aresource conflict while con-figuring a plug and play ISAor PCI expansion card.See “Resolving Resource Conflicts” in Chap-ter 5.Expansion ROM not ini-tializedThe BIOS detected aresource conflict while con-figuring a plug and play ISAor PCI expansion card.See “Resolving Resource Conflicts” in Chap-ter 5.System configurationdata write errorA chip on the system boardmay be malfunctioning.Run the System Set tests in system diagnostics.See the chapter titled “Running the Diskette-Based Diagnostics” in your Diagnostics andTroubleshooting Guide. A faulty chip on the sys-tem board usually requires that you replace thesystem board.System memory size haschanged - Run Configu-ration UtilityDIMM memory may havebeen added or removed, orone or more DIMMs may beimproperly seated or faulty.Run the EISA Configuration Utility (see thechapter titled “Using the EISA ConfigurationUtility”). Remove and reseat the DIMMs. (See“Removing a DIMM” and “Installing a DIMM”in Chapter 7.) If the problem persists, run theRAM Test Group in the system diagnostics. Seethe chapter titled “Running the Diskette-BasedDiagnostics” in your Diagnostics and Trouble-shooting Guide for instructions.Table F-1. System Error Messages (continued)Message Probable Cause Corrective ActionNOTE: For the full name of an abbreviation or acronym used in this table, see the Glossary.