10 Installing the HardwareEnvironmental ParametersPower SupplyWidth 17 inches (432 mm) 17 inches (432 mm)Depth 16.73 inches (425 mm) 16.73 inches (425 mm)Chassis weight withfactory-installedcomponents12 pounds (5.5 kg) 12 pounds (5.5 kg)Rack clearance required Front: 5-inches (12.7 cm)Rear: 5-inches (12.7 cm)Front: 5-inches (12.7 cm)Rear: 5-inches (12.7 cm)Parameter S2410P S2410CPTemperature 32° to 104°F (0° to 40°C)-40° to 158°F (-20° to 70°C)32° to 104°F (0° to 40°C)-40° to 158°F (-20° to 70°C)Thermal Dissipation(Maximum ThermalOutput)S2410P: 768.2 BTU/Hour S2410CP: 426.8 BTU/HourMaximum altitude No performance degradationto 10,000 feet (3,048 meters)No performance degradationto 10,000 feet (3,048 meters)Relative humidity Operating: 10 to 90% relativehumidity (RH) non-condensingStorage: 10 to 95% RH non-condensingOperating: 10 to 90% relativehumidity (RH) non-condensingStorage: 10 to 95% RH non-condensingShock MIL-STD-810 MIL-STD-810Vibration Telcordia GR-63-CORE Telcordia GR-63-COREISO 7779 A-weightedsound pressure levelS2410P: 61.5 dBA at 73.4°F(23°C)S2410CP: 61.5 dBA at 73.4°F(23°C)Parameter S2410P S2410CPNominal Input Voltage 100 - 240 VAC, 50/60 Hz,auto-sensing100 - 240 VAC, 50/60 Hz,auto-sensingParameter S2410P S2410CP