Configuring Connectivity Fault Management 775Configuring Dot1ag (CLI)This section provides information about the commands you use to configureDot1ag settings on the switch. For more information about the commands,see thePowerConnect M6220/M6348/M8024/M8024-k CLI Reference Guideat support.dell.com/manuals.Configuring Dot1ag Global Settings and Creating DomainsBeginning in Privileged Exec mode, use the following commands to configureCFM settings and to view global status and domain information.CLI Command Descriptionconfigure Enter global configuration mode.ethernet cfm enable Enables connectivity fault management services.ethernet cfm mep archive-hold-timetimeSet the time interval (range: 1–65535 seconds) afterwhich inactive RMEPs are removed.ethernet cfm cc levellevel vlanvlan-id interval {1 | 10 | 60 |600}Configure the Continuity Check Message (CCM)transmit interval for the specified VLAN.ethernet cfm domainnamelevellevelCreate a maintenance domain (MD) by assigning aname and level (0–7), and enter MaintenanceDomain Config mode for that MD.servicename vlanvlan-id Create a maintenance association (MA) within thecurrent MD by associating it with a VLAN andnaming the association (as a service instance).exit Exit to privileged Exec Modeshow ethernet cfm domainbriefDisplay the configured parameters in theMaintenance Domain.