Tower-to-Rack Conversion Guide 19Installing the Optional 1x2 Flex Bay BracketNOTE: The rack front panel is keyed so that the 1x2 flex bay bracket installs in the opposite orientation as thetower front panel.1 Insert the 1x2 flex bay bracket three-quarters of the way into the peripheral bay.2 Reconnect the power cable to the flex bay backplane. See Figure 1-8.3 Reconnect the SAS cables to the connectors on the flex bay backplane. See Figure 1-8.4 Push the flex bay bracket the rest of the way into the peripheral bay until the spring latch on top of theperipheral bay engages.Figure 1-8. Installing the Optional 1x2 Flex Bay Bracket1 peripheral bay spring latch 2 SAS cable (SAS_B_INconnector)3 SAS cable (SAS_B_OUTconnector)4 power connector 5 1x2 flex bay drive bracket 6 slot key7 flex bay5671 234book.book Page 19 Friday, May 26, 2006 3:03 PM