12 Using the Baseboard Management Controllerw w w . d e l l . c o m | s u p p o r t . d e l l . c o m • System Board 1.5V ESB2 PG• System Board 1.5V PG• System Board 1.8V PG• System Board 3.3V PG• System Board 5V PG• System Board Backplane PG• System Board CPU VTT• System Board Linear PGConsoleConsole Redirection and Virtual MediaThe Console Redirection page enables you to use the display, mouse, and keyboard on the localmanagement station to control the corresponding devices on a remote managed system. You canrun a maximum of four simultaneous console redirection sessions.NOTE: Before you can use the console redirection feature, your browser must have the Java VideoViewer installed. This feature needs Java 1.5.15 or later installed on the host system. If the iBMC detectsthat the Java Video Viewer is not installed, you are prompted to install it.NOTE: Sometimes the Console is referred to as the Session Viewer.NOTE: The recommended display resolution on the management station (or client) is at least 1280 x 1024pixels at 60 Hz with 32 bit color. You cannot view the console in full screen mode if your monitor resolutionis less than this minimum.Table 1-12. Voltage Probe ListItem DescriptionStatus See Table 1-11.Probe Name Name of the sensor.Reading Good indicates that the current voltage is between the minimum andmaximum warning thresholds.Table 1-13. Console Redirection DescriptionsItem DescriptionConsole Redirection Enabled Yes indicates that Console Redirection is enabled.Video Encryption Enabled Yes indicates that Video Encryption is enabled.Max Sessions Displays the maximum number of console redirection sessions thatare possible.