Dell Manager 2014 When formatting completes, press any key to display the previousmenu.Rebuilding Failed Disk DrivesIf a physical drive fails in an array configured as a RAID 1 or 5 logical drive,you can recover the lost data by rebuilding the drive. If a rebuilding sparefails, a new rebuild is started using a second spare, if available. The capacityof the second spare must be equal to or greater than the failed drive.Table 12-9 describes the rebuild types.Manual Rebuild – Rebuilding an Individual DrivePerform the following steps to rebuild one drive:1 Choose Objects—> Physical Drive on the Management Menu.A window displays the devices connected to the current controller.2 Press the arrow keys to select the physical drive to be rebuilt and press.3 Choose Rebuild from the physical drive action menu and respond tothe confirmation prompt.Rebuilding can take some time, depending on the drive capacity.4 When rebuild completes, press any key to display the previous menu.Ta b l e 1 2 - 9 . R e b u i l d Ty p e sType DescriptionAutomaticRebuildIf you have configured hot spares, PERC 3 automatically tries touse them to rebuild failed disks. Display the Objects—> PhysicalDrive screen while a rebuild is in progress. The drive indicator forthe hot spare disk drive has changed to REBLD A[array number]-[drive number], indicating the disk drive being replaced by the hotspare.ManualRebuildManual rebuild is necessary if no hot spares with enough capacity torebuild the failed drives are available. Select the Rebuild option onthe Management Menu or the Objects—> Physical Drive menu.