NOTE: Install the server module partitions to install half-height server module(s). For moreinformation, see the Dell PowerEdge VRTX Enclosure Owner’s Manual at dell.com/poweredgemanuals.Steps1. If you are installing a new server module, remove the plastic cover from the I/O connector(s) andsave for future use.2. Orient the server module so that the module handle is on the left side of the server module.CAUTION: While installing the server modules, ensure that they are properly aligned with theslots, to prevent damage to the server module connectors.3. Align the server module with the server module slot and guide rails on the enclosure.4. Slide the server module into the enclosure until the module release handle engages and the servermodule is locked in place.Next steps1. Turn on the server module.2. If applicable, install the front bezel of the PowerEdge VRTX enclosure.Removing and installing the system coverRemoving the system coverPrerequisites1. Ensure that you read the Safety instructions.2. Turn off the server module using CMC.3. Remove the server module from the enclosure.4. Install the I/O connector cover.Steps1. Press the release button and slide the cover toward the back of the server module.2. Lift the cover away from the server module.40