Figure 72. Removing a DC PSU1. release latch 2. power supply status indicator3. PSU 4. power connector5. PSU handleRelated LinksSafety instructionsInstalling a DC power supply unitInstalling a DC power supply unitPrerequisitesWARNING: For equipment using –(48–60) V DC power supply units (PSUs), a qualified electricianmust perform all connections to DC power and to safety grounds. Do not attempt connecting toDC power or installing grounds yourself. All electrical wiring must comply with applicable localor national codes and practices. Damage due to servicing that is not authorized by Dell is notcovered by your warranty. Read and follow all safety instructions that came with the product.1. Follow the safety guidelines listed in the Safety instructions section.2. Follow the procedure listed in the Before working inside your system section.3. If installed, remove the PSU blank.4. Verify that both the PSUs are of the same type and have the same maximum output power.NOTE: The maximum output power (shown in watts) is listed on the PSU label.Steps1. Slide the PSU into the chassis until the PSU is fully seated and the release latch snaps into place.NOTE: If you have unlatched the cable management arm, relatch it. For information about thecable management arm, see the system’s rack documentation.2. Connect the safety ground wire.3. Install the DC power connector in the PSU.155