March 200812For more information visit: www.eaton.com CA04801001EOperator Interface ProductsHMi Operator InterfaceSoftware and AccessoriesTable 12. HMIEC0806/HMIEC1612 Function Specifications M1000, M1001, M1002, M1003, M1020, M1021, M1022, M1067, M10068, and M1161 are thespecial auxiliary relays (special M).Item Specifications RemarkControl Method Stored program, cyclicscan system—I/O Processing Method Batch I/O (refresh) Immediate refresh command available onlywith I/O of the MPUExecution Speed Basic command (30 us) Application command (30 ~ hundreds us)Program Language Commands + LadderDiagram + SFCStep commands includedProgram Capacity 999 Steps Built-in EEPROMCommands Basic commands: 32(including the STLcommands)Application commands: 59Step Relay(Latched)General StepPoint128 Points S0 ~ S127AuxiliaryRelayGeneral 1024 Points M0 ~ M511, M768 ~ M999, 744 points;M1000 ~ M1279, 280 points Latched 256 Points M512 ~ M767Timer Digital 64 Points T0 ~ T63 (100 ms time base)63 Points T64 ~ T126 (10 ms time base)1 Points T127 (1 ms time base)Counter General 112 Points C0 ~ C111Latched 16 Points C112 ~ C12732 bit 13 Points C235,C236,C237,C238,C241,C242,C244,C246,C247,C249,C251,C252, C254(all of them are latched type)DataRegisterGeneral 408 Points D0 ~ D407Latched 192 Points D408 ~ D599Pointer P 64 Points P0 ~ P63IndexRegisterE / F 2 E, FConstant Decimal K 16 bit: -32768 ~ +32767 32 bit: -2147483648 ~ +2147483647Hexadecimal H 16 bit: 0000 ~ FFFF 32 bit: 00000000 ~ FFFFFFFFSelf Diagnosis / Protection I/O check, system execution timeout check, invalid command check,program check and password settingsMonitor / Debug Program execution time display, bit / word, device settings