INSTALLATION INSTRUCTIONS/WIRING14PANEL MOUNTINGThe panel mounting kit includes: (1) mounting gas-ket, (2) mounting clips and (2) screws. Refer to thedimension diagram in Figure 5 for a drawing of thecorrect installation of these parts.The mounting gasket is coated on one side with acontact adhesive and a paper backing. Careshould be taken during the gasket installation thatthe gasket be correctly positioned on the panel atthe first attempt. Attempting to re-position the gas-ket once the adhesive has come in contact withthe panel is likely to deform or tear the gasket.This may result in an improper seal. For bestresults, follow these directions:1. Stand the counter on a desk or table with itsdisplay down, screw terminals up.2. Remove and discard the center square of thegasket at the scribe marks in the gasket andpaper backing. Do not remove the backingfrom the remaining outer rim.3. Slide the gasket down the unit until it is in posi-tion at the rear of the unit’s front bezel. Thepaper backing side should be up.4. Insert the tip of a knife between the paper andthe gasket and, while holding the gasket downto the unit with the knife, peel off the paperbacking.5. Slide the unit through the panel cutout until thegasket firmly adheres to the panel.6. Install the mounting clips and screws asshown in the diagram above. Do not overtighten the mounting screws. The screwsshould be tight enough to firmly hold the unit inplace, but not so tight as to squeeze the gas-ket out from behind the front bezel.7. A switch shall be included in the buildinginstallation:• It shall be in close proximity to the equip-ment and within easy reach of the opera-tor.• It shall be marked as the disconnectingdevice for the equipment.• Switches and circuit breakers in Europemust comply with IEC 947.Figure 8. 115 VAC 47/63 Hz Power Connection