www.powerware.com 1.800.356.5794SOFTWARE AND CONNECTIVITY OPTIONSBundled with Software Suite CD and communication cable. See the software and connectivity product section for more detail.UNIVERSAL MODULE ASY-0 RUNTIME CHART IN MINUTES (FULL LOAD/HALF LOAD)Load (VA) Number of strings (2 battery modules per string; 2 battery modules occupy 1-slot)1 String 2 String 3 String 4 String 5 String 6 String 7 String 8 String 9 String 10 String 11 String 12 String3 kVA 8/24 24/59 43/95 58/140 80/175 95/125 119/240 135/290 155/335 165/365 200/395 215/4506 kVA 8/24 16/40 24/59 32/83 40/103 49/114 58/140 69/156 83/175 90/190 103/2059 kVA 8/24 13/35 18/46 24/59 29/63 35/86 40/103 46/115 54/125 58/14012 kVA 8/24 13/33 16/40 19.5/43.5 24/59 29/70 33/80 36/90 41/10015 kVA 8/24 11.5/31 14.5/31.5 18/46 20.5/51 24/58 28/66 31/7318 kVA 8/24 11/31.5 13/36 15.5/41 18/45 20.5/51 24/58Additional battery runtimes available up to 8 hours. Please contact your Powerware representative.13 String 14 String 15 String 16 String 17 String 18 String 19 String 20 String 21 String 22 String 23 String 24 String3 kVA 225/500 245/540 270/600 290/620 315/650 335/690 350/720 365/780 375/850 395/890 425/920 450/9506 kVA 113/335 123/255 135/273 143/290 148/315 156/333 165/350 175/365 183/385 190/395 198/420 205/4409 kVA 63/150 73/165 80/178 86/190 93/200 100/210 107/225 115/240 121/255 125/270 135/280 143/29012 kVA 47/110 52/121 56/130 58/140 65/147 70/156 75/165 80/175 85/185 90/195 95/205 100/21515 kVA 34/83 38/94 41.5/103 44.5/113 46.5/117 51/127 56/130 58/140 61/149 66/158 71/165 73/17018 kVA 27/65 31.5/72 34.5/77 36/83 38/94 41/100 44/105 45/115 48/122 54/131 57/137 58/140Battery strings above and to the right of the dark line require additional (N+X) power modules or a 20A charger module.SPLIT-PHASE MODULE ASY-0 RUNTIME CHART IN MINUTES (FULL LOAD/HALF LOAD)Load (VA) Number of Strings (2 battery modules per string; 2 battery modules occupy 1-slot)1 String 2 String 3 String 4 String 5 String 6 String 7 String 8 String 9 String 10 String 11 String 12 String3 kVA 6.5/16 16/40 27.5/67.5 40/98 53.5/132 67.5/167 83/204 98/242 115/283 132/324 149/365 167/4086 kVA 6.5/16 11/27.5 16/40 21.5/53.5 27.5/68 33.5/83 40/98 46.5/115 53.5/132 60.5/149 67.5/1679 kVA 6.5/16 9.5/23.5 13/31.5 16/40 20/49 23.5/58 27.5/67.5 31.5/78 35.5/88 40/9812 kVA 6.5/16 9/21.5 11/27.5 13.5/33.5 16/40 19/46.5 21.5/53.5 24.5/60.5 27.5/6815 kVA 6.5/16 8/20.5 10/25 12/30 14/35 16/40 18.5/45 20.5/50.518 kVA 6.5/16 8/20 9.5/23.5 11/27.5 12.5/30 14.5/35.5 16/40Additional battery runtimes available up to 8 hr. Please contact your Powerware representative. Split-phase Module is for U.S. use.13 String 14 String 15 String 16 String 17 String 18 String 19 String 20 String 21 String 22 String 23 String 24 String3 kVA 185/456 204/501 223/549 242/595 262/640 283/692 302/750 323/790 345/850 365/900 387/955 408/10156 kVA 75/185 83/204 90/223 98/242 106/262 115/285 123/302 132/324 140/345 149/365 157/388 167/4089 kVA 44/109 49/120 53.5/132 58/143 63/154 68/167 73/179 78/191 83/204 88/210 93/229 98/24212 kVA 30.5/75 33.5/83 37/90 40/98 43/106 46.5/115 50/123 53.5/132 57/140 60/149 64/157 68/16715 kVA 23/56 25/62 27.5/67.5 30/73.5 32.5/79.5 35/86 37.5/92 40/98 42.5/105 45/111 48/118 51/12418 kVA 18/44 20/49 21.5/53.5 23.5/58 25.5/63 27.5/68 29.5/73 31.5/78 33.5/83 35.5/88 38/93 40/98Battery strings above and to the right of the dark line require additional (N+X) power modules or a 20A charger module.CUSTOMIZABLE INPUT PLUG OPTIONS1Input Plug Power Module Type CTO Digit List PriceL6-30P2 Universal C $109L14-20P3 Split-Phase F $109L14-30P2 Split-Phase G $12914-50P4 Split-Phase H $1491. May be configured to order through or sales office: 800.356.5794. 2. Limits chassis to maximum current of 24A and three power modules for 5 kVA redundant. 3. Limits chassis to maximum current of16A and two power modules for 3 kVA redundant. 4. Limits chassis to maximum current of 40A and four power modules for 8 kVA redundant.SINGLE-PHASE SERIES 9Powerware 9170+ (continued)