Dimn ‘a’Dimn ‘a’Instruction Leaflet K1121V3LeatJuly 2018 Product luminaires comply with EN60598 and are suitable for use in normal interior conditions.o o This luminaire has an ambient temperature range of -10 C to 25 C for the non-emergency versiono o For Emergency variants - This luminaire has an ambient temperature range of 5 C to 25 C, to ensure the batteries work correctly1 Recessed - Bracket InstallationFixing Centres (per fitting)1.0m1.5m2.0m700mm2700mm + centre fixing3.0m1200mm1700mmIMPORTANT: Once bracketsare fully installed. Plaster surfacebefore installing the Leat.a)Cut aperture to required size.Using the flat bracket (sold separately) as a drilling template, drill 4 x holes5mm dia, through pilot holes. See ‘Bracket Orientation’.Counter sink the drilled holes so c/sk screws (supplied) sit flush withthe plasterboard.ApertureTrim - 65.5mm wideTrimless - 57.0mm wideFixing crsDimn ‘a’Drilling Direction240mm MAX Plasterboard160mm MIN44x44mmWoodenBattensRecommended Wooden Batten SpacingFor Plasterboard SupportDrilling Directionb) Secure each slider toplasterboard using M5c/sk screws suppliedDim ‘a’TrimmedTrimless79.0mm76.0mmBracket OrientationWhen using the flat bracket for the drill hole locations make sure the metalwork isin the correct orientation.The image on the left shows the orientation for the trimless variant and the image onthe right shows the orientation for the trimmed version.c) Fold flat bracket over and fix spring clip.Fit main bracket into slider brackets. Ensure thatdimension ‘a’ from bottom of plasterboard to the insideface of main face is adhered to. Tighten sliderbracket screws to hold main bracket in place.Dim ‘a’