Technical Specification Menvier30Page 38EN50131-6 ratingsThe Menvier30 provides space for one 17Ahbattery. (If required the installer can fit a 7Ahbattery in place of the 17Ah battery.)For Security Grade 2 the required battery standbytime during mains fail is 12 hours. This means thatall the devices powered by the backup battery,including the control unit and at least one keypad,should together draw no more in total than anaverage of 580mA over a 12 hour standby time fora 7Ah battery.The table below shows the current consumption ofthe control unit and each device that can be fittedto it.CIE powerrequirement:100mA min.120mA maxi-kp01 powerrequirement:30mA (backlight off)45mA/65mA (backlightnorm/bright)60mA in alarmKEY-KPZ01/KP01/K01power requirement35mA backlight OFF,internal prox reader only.65mA max backlight ON,external prox readerconnectedWired Expanderrequirement20mA max quiescent.300mA in alarm ifsounder connected.Radio Expanderrequirement40mA max quiescent320mA in alarm ifsounder connected.Battery chargingrequirement:200mA (recharge within72 hrs)Plug-onCommunicator powerrequirement:i-sd02, i-dig02:20mA quiescent50mA maxPlug-onCommunicator powerrequirementi-gsm02:150mA quiescentand max.Plug-byCommunicator pinsrequire:5mA each when active.10 FSL zones 20mA5 four-wire CCL zones 30mA12V Bus outputvoltage range :10±0.5V to 13.8V12V Aux outputvoltage range:10±0.5V to 13.8V12V Bell outputvoltage range10±0.5V to 13.8VMax p-to-p ripplevoltage:0.5VStandby Battery: 12V, 7Ah sealed leadacid (not supplied).‘Low battery’ fault at: < 12VAux power output faultat:< 9VDeep dischargeprotection at:10±0.5VServiceablecomponents:Mains fuse: 250mA (T)Standby time: See “Power Availability” onpage 12.ElectromagneticCompatibilityImmunity Conforms to EN50130-4.Emissions Conforms to EN61000-6-3.OutputsPanel:O/P 1,Bell,StrobeOpen collector transistor,+12VDC when inactive, 0Vwhen active. 500mA max.Plug-by O/P 1-12Open collector transistor+12VDC when inactive, 0Vwhen active, 50mA max.LS(loudspeaker)Min impedance 16 Ohm peroutput, current consumption =280mA in alarm.Expander:OutputsOpen collector transistor,+12VDC when inactive, 0Vwhen active. 500mA max.Note: The current is limited bythe amount available from thepower supply driving theexpander.KEY-KPZ01OutputsOpen collector transistor,+12VDC when inactive, 0Vwhen active, 500mA max.Sounder Volume Levels (at 1m)i-kp01 (at max volume) 70dBExpander piezo sounder 70dBPanel/Expander 16 Ohm loudspeaker 93dBFusesThe control unit has a replaceable T250mA mainsfuse.Electrical SafetyConforms to EN60950-1.OtherIf you wish to connect the Menvier30 control unitto a PC using the USB port then make sure thatthe cables have the following specifications:USB Mini-B plug for control unit end,USB-A for PC end. Max length3m.Radio Expander and KeypadsRadio Operating frequency868.6625MHz Narrowband.EN 300 220-3.EN 300 330-2