19o MIC1 and MIC2 with different priorities: When the microphone withthe higher priority, whose Talkover is assigned to a destination zone, isactivated (its signal exceeds the detection threshold), it disables theTalkover of the other microphone in the same zone. If the microphonewith a lower priority has its Talkover function activated at a givenmoment, the activation of the microphone with the higher priority wouldalso interrupt it until the higher priority Talkover ceases actuating (afterits signal drops below the activation threshold again) TALKOVER THRESHOLD: trigger threshold of the Talkover function. Themicrophone signal in question activates its Talkover function when said thresholdis exceeded. This trigger level depends on the sensibility level of the microphone(rear panel), but is independent of the VOL adjustment of the MIC inputsADVANCED adjustments menu TALKOVER ATTACK: the time the Talkover function takes to actuate, from themoment the microphone signal exceeds the trigger threshold TALKOVER RELEASE: The time the Talkover function takes to cease actuating,from the moment the microphone signal drops below the trigger threshold again TALKOVER DEPTH: The attenuation applied by the Talkover function on theactive line signal when triggered NOISE GATE: noise gate function for the microphone input. When this function isactive, the MIC input is muted whilst there is no signal above the NOISE GATEfunction activation threshold, such that the unit rejects the background noise capturedby the microphone connected to it NOISE GATE THRESHOLD: NOISE GATE function trigger threshold4.4. AUTO STANDBY FunctionThe CA200z's AUTO STANDBY (rest or power saving mode) enables leaving the deviceconnected to the mains indefinitely such that the rest mode can be automatically deactivated whenthere is an input signal and activated when there is none.To enable AUTO STANDBY mode, the mode's ON option must be activated in specialsetup mode. See section 4.2 Special setup mode for more details.One of the following two situations may occur when the AUTO STANDBY mode isenabled:a) There is NO audio signal in the inputs. Result: the amplifier immediately goes intoAUTO STANDBY modeb) If there is an audio signal in the inputs. Result: the amplifier stays activeWhen it is enabled and there is no audio signal (or a very weak one below the activationthreshold) in any of the unit's inputs for two minutes or more, the CA200z automatically goes intoAUTO STANDBY mode, and the ON/STBY LED lights up in green with orange flashes, and the LEDindicators for the inputs and LCD screen switch off.If the front panel controls or infrared remote control are actuated while the CA200z is inAUTO STANDBY mode, the LCD screen will light up for a short period (even when the LCD