GE Multilin D60 Line Distance Relay 5-275 SETTINGS 5.2 PRODUCT SETUP55.2.11 USER-PROGRAMMABLE SELF-TESTSPATH: SETTINGS ! PRODUCT SETUP !" USER-PROGRAMMABLE SELF TESTSAll major self-test alarms are reported automatically with their corresponding FlexLogicô operands, events, and targets.Most of the Minor Alarms can be disabled if desired.When in the ìDisabledî mode, minor alarms will not assert a FlexLogicô operand, write to the event recorder, display targetmessages. Moreover, they will not trigger the ANY MINOR ALARM or ANY SELF-TEST messages. When in the ìEnabledî mode,minor alarms continue to function along with other major and minor alarms. Refer to the Relay Self-Tests section in Chapter7 for additional information on major and minor self-test alarms.5.2.12 CONTROL PUSHBUTTONSPATH: SETTINGS ! PRODUCT SETUP !" CONTROL PUSHBUTTONS ! CONTROL PUSHBUTTON 1(7)The three standard pushbuttons located on the top left panel of the faceplate are user-programmable and can be used forvarious applications such as performing an LED test, switching setting groups, and invoking and scrolling though user-pro-grammable displays, etc. Firmware revisions 3.2x and older use these three pushbuttons for manual breaker control. Thisfunctionality has been retained ñ if the Breaker Control feature is configured to use the three pushbuttons, they cannot beused as user-programmable control pushbuttons. The location of the control pushbuttons in the following figure.An additonal four control pushbuttons are included when the D60 is ordered with twelve user programmable pushbuttons.# USER-PROGRAMMABLE# SELF TESTSDIRECT RING BREAKFUNCTION: EnabledRange: Disabled, Enabled.Valid for units equipped with Direct I/O Module.MESSAGE DIRECT DEVICE OFFFUNCTION: EnabledRange: Disabled, Enabled.Valid for units equipped with Direct I/O Module.MESSAGE REMOTE DEVICE OFFFUNCTION: EnabledRange: Disabled, Enabled.Valid for units equipped with CPU Type C or D.MESSAGE PRI. ETHERNET FAILFUNCTION: DisabledRange: Disabled, Enabled.Valid for units equipped with CPU Type C or D.MESSAGE SEC. ETHERNET FAILFUNCTION: DisabledRange: Disabled, Enabled.Valid for units equipped with CPU Type D.MESSAGE BATTERY FAILFUNCTION: EnabledRange: Disabled, Enabled.MESSAGE SNTP FAILFUNCTION: EnabledRange: Disabled, Enabled.Valid for units equipped with CPU Type C or D.MESSAGE IRIG-B FAILFUNCTION: EnabledRange: Disabled, Enabled.# CONTROL# PUSHBUTTON 1CONTROL PUSHBUTTON 1FUNCTION: DisabledRange: Disabled, EnabledMESSAGE CONTROL PUSHBUTTON 1EVENTS: DisabledRange: Disabled, Enabled