44 49-60805-1Performance Data SheetSmartWater™ Filtration System—GE Appliances MWF CartridgeThe concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to theSHUPLVVLEOHOLPLWIRUZDWHUOHDYLQJWKHV\VWHPDVVSHFLILHGLQ16)$16,6WDQGDUGDQG6WDQGDUG6\VWHPWHVWHGDQGFHUWLILHGE\16),QWHUQDWLRQDODJDLQVW16)$16,6WDQGDUGDQG6WDQGDUGIRUWKHUHGXFWLRQRIVXEVWDQFHVOLVWHGEHORZThe following pharmaceutical reduction claims have not been certified by NSF International or the state of California.Claims tested and verified by independent laboratory:ContaminantReductionAverageInfluentNSF specifiedChallengeConcentrationAvg %ReductionAverageProduct WaterConcentrationMax PermissibleProduct WaterConcentrationNSF ReductionRequirementsNSFTest ReportAtenolol 978 ng/L N/A 99.5% 5.0 ng/L N/A N/A J-00121587Fluoxetine 907 ng/l N/A 99.4% 5.4 ng/L N/A N/A J-00121587Ibuprofen 885 ng/L N/A 94.1% 52.3 ng/L N/A N/A J-00121588Progesterone 1097 ng/L N/A 99.5% 5.0 ng/L N/A N/A J-00121589Trimethoprim 415 ng/L N/A 99.5% 2.0 ng/L N/A N/A J-00121587,WLVHVVHQWLDOWKDWWKHPDQXIDFWXUHU¶VUHFRPPHQGHGLQVWDOODWLRQPDLQWHQDQFHDQGILOWHUUHSODFHPHQWUHTXLUHPHQWVEHFDUULHGRXWIRUWKHSURGXFWWRSHUIRUPDVDGYHUWLVHG6HH,QVWDOODWLRQ0DQXDOIRU:DUUDQW\LQIRUPDWLRQApplication Guidelines/Water Supply Parameters6HUYLFH)ORZ 0.5 gpm (21.9 lpm)Water Supply Potable WaterWater Pressure 40-120 psi (276-827 kPa)Water Temperature )) &&Capacity 300 Gallons (1,135 Liters). Contaminant Reduction Determined by NSF testing.Substance Testedfor ReductionAverageInfluentNSF specifiedChallengeConcentrationAvg %ReductionAverageProduct WaterConcentrationMax PermissibleProduct WaterConcentrationNSF ReductionRequirementsNSFTest ReportChlorine Taste and Odor 2.0 mg/L 2.0 mg/L ± 10% 97.4% 0.05 mg/L N/A J-00137878Nominal Particulate Class,WRP 11,333,333 pts/mL At least 10,000 particles/mL 99.9% 5,510 pts/mL N/A J-00137881Cyst* 101,000 cysts/L Minimum 50,000 cysts/L 99.99% 1 cyst/L N/A J-00100036Asbestos 133 MF/L 10 7 to 10 8 fibers/L; fibersJUHDWHUWKDQPLQOHQJWK >99% 0)/ N/A J-00137886Atrazine 0.008 mg/L 0.009 mg/L ± 10% 91.3% 0.0007 mg/L 0.003 mg/L N/A J-00137910Benzene 0.014 mg/L 0.015 mg/L ± 10%± 96.5% 0.0005 mg/L 0.005 mg/L N/A J-00137912Carbofuran 0.08 mg/L 0.08 mg/L ± 10% 74.5% 0.01 mg/L 0.04 mg/L N/A J-00147488Endrin 0.007 mg/L 0.006 mg/L ± 10% 97.1% 0.0002 mg/L 0.002 mg/L N/A J-00100039Lead @ pH 6.5 0.148 mg/L 0.15 mg/L ± 10% 99.3% 0.001 mg/L 0.010 mg/L N/A J-00137914Lead @ pH 8.5 0.155 mg/L 0.15 mg/L ± 10% 99.3% 0.001 mg/L 0.010 mg/L N/A J-00137915Lindane 0.002 mg/L 0.002 mg/L ± 10% 96.5% 0.00002 mg/L 0.0002 mg/L N/A J-00137924Mercury @ pH 6.5 0.006 mg/L 0.006 mg/L ± 10% 87.6% 0.0004 mg/L 0.002 mg/L N/A J-00137925Mercury @ pH 8.5 0.006 mg/L 0.006 mg/L ± 10% 93.2% 0.0007 mg/L 0.07 mg/L N/A J-00092355P-Dichlorobenzene 0.223 mg/L 0.225 mg/L ± 10% 99.8% 0.005 mg/L 0.075 mg/L N/A J-00137926Tetrachloroethylene 0.014 mg/L 0.015 mg/L ± 10% 96.5% 0.0005 mg/L 0.005 mg/L N/A J-00137929Toxaphene 0.017 mg/L 0.015 mg/L ± 10% >93.9% 0.001 mg/L 0.003 mg/L N/A J-001379282, 4-D 0.192 mg/L 0.210 mg/L ± 10% 77.7% 0.040 mg/L 0.07 mg/L N/A J-00147489*Based on the use of Cryptosporidium parvum oocysts.NOTE: While the testing was performed under standard laboratoryconditions, actual performance may vary. Contaminant reductiontesting is conducted every five years by certifying agency tomaintain certification.5HSODFHPHQW&DUWULGJH0:))RUHVWLPDWHGFRVWVRIUHSODFHPHQWelements please call 1.877.959.8688 or visit our website atgeapplianceparts.com.WARNINGTo reduce the risk associated with ingestion of contaminants:• Do not use with water that is microbiologically unsafe or ofunknown quality without adequate disinfection before andafter the system. Systems certified for cyst reduction may beused on disinfected water that may contain filterable cysts.NOTICETo reduce the risk associated with property damage due towater leakage:• Read and follow use instructions before installation and use ofthis system.,QVWDOODWLRQDQGXVHMUST comply with all state and localplumbing codes.• Do notLQVWDOOLIZDWHUSUHVVXUHH[FHHGVSVL N3D ,Iyour water pressure exceeds 80 psi (552 kPa), you must installa pressure-limiting valve. Contact a plumbing professional if youare uncertain how to check your water pressure.• Do notLQVWDOOZKHUHZDWHUKDPPHUFRQGLWLRQVPD\RFFXU,Iwater hammer conditions exist you must install a water hammerarrester. Contact a plumbing professional if you are uncertainhow to check for this condition.• Do not install on hot water supply lines. The maximum operatingZDWHUWHPSHUDWXUHRIWKLVILOWHUV\VWHPLV) & • Protect filter from freezing. 'UDLQILOWHUZKHQWHPSHUDWXUHVGURSEHORZ) & • The disposable filter cartridge should be replaced every 6months at the rated capacity, or sooner if a noticeable reductionin flow rate occurs.Tested and certified by NSF International againstNSF/ANSI Standard 42 and Standard 53 in modelGE Appliances MWF for the reduction of theclaims specified on the performance data sheet.REPLACEMENTELEMENT