B-26 M60 Motor Protection System GE MultilinB.4 MEMORY MAPPING APPENDIX BB4706 Breaker 1 Close 0 to 65535 --- 1 F300 04707 Breaker 1 Phase A / Three-pole Closed 0 to 65535 --- 1 F300 04708 Breaker 1 Phase B Closed 0 to 65535 --- 1 F300 04709 Breaker 1 Phase C Closed 0 to 65535 --- 1 F300 0470A Breaker 1 External Alarm 0 to 65535 --- 1 F300 0470B Breaker 1 Alarm Delay 0 to 1000000 s 0.001 F003 0470D Breaker 1 Pushbutton Control 0 to 1 --- 1 F102 0 (Disabled)470E Breaker 1 Manual Close Recall Time 0 to 1000000 s 0.001 F003 04710 Breaker 1 Out of Service 0 to 65535 --- 1 F300 04711 Breaker 1 Block Open 0 to 65535 --- 1 F300 04712 Breaker 1 Block Close 0 to 65535 --- 1 F300 04713 Breaker 1 Phase A / Three-pole Opened 0 to 65535 --- 1 F300 04714 Breaker 1 Phase B Opened 0 to 65535 --- 1 F300 04715 Breaker 1 Phase C Opened 0 to 65535 --- 1 F300 04716 Breaker 1 Operate Time 0 to 2 s 0.001 F001 704717 Breaker 1 Events 0 to 1 --- 1 F102 0 (Disabled)4718 Reserved 0 to 65535 s 1 F001 04719 ...Repeated for Breaker 24732 ...Repeated for Breaker 3474B ...Repeated for Breaker 4Flexcurves A and B (Read/Write Settings)4800 FlexCurve A (120 items) 0 to 65535 ms 1 F011 048F0 FlexCurve B (120 items) 0 to 65535 ms 1 F011 0Modbus User Map (Read/Write Setting)4A00 Modbus Address Settings for User Map (256 items) 0 to 65535 --- 1 F001 0User Displays Settings (Read/Write Setting) (16 modules)4C00 User-Definable Display 1 Top Line Text --- --- --- F202 “ “4C0A User-Definable Display 1 Bottom Line Text --- --- --- F202 ““4C14 Modbus Addresses of Display 1 Items (5 items) 0 to 65535 --- 1 F001 04C19 Reserved (7 items) --- --- --- F001 04C20 ...Repeated for User-Definable Display 24C40 ...Repeated for User-Definable Display 34C60 ...Repeated for User-Definable Display 44C80 ...Repeated for User-Definable Display 54CA0 ...Repeated for User-Definable Display 64CC0 ...Repeated for User-Definable Display 74CE0 ...Repeated for User-Definable Display 84D00 ...Repeated for User-Definable Display 94D20 ...Repeated for User-Definable Display 104D40 ...Repeated for User-Definable Display 114D60 ...Repeated for User-Definable Display 124D80 ...Repeated for User-Definable Display 134DA0 ...Repeated for User-Definable Display 144DC0 ...Repeated for User-Definable Display 154DE0 ...Repeated for User-Definable Display 16Field Unit Raw Data Actuals (Read Only) (8 modules)4E00 Raw Field Data AC1 Mag 0 to 0.001 A 0.001 F003 04E02 Raw Field Data AC1 Angle 0 to 0.1 degree 0.1 F002 04E03 Raw Field Data AC2 Mag 0 to 0.001 A 0.001 F003 04E05 Raw Field Data AC2 Angle 0 to 0.1 degree 0.1 F002 04E06 Raw Field Data AC3 Mag 0 to 0.001 A 0.001 F003 04E08 Raw Field Data AC3 Angle 0 to 0.01 degree 0.1 F002 04E09 Raw Field Data AC4 Mag 0 to 0.001 A 0.001 F003 04E0B Raw Field Data AC4 Angle 0 to 0.01 degree 0.1 F002 0Table B–9: MODBUS MEMORY MAP (Sheet 19 of 59)ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT