B-34 M60 Motor Protection System GE MultilinB.4 MEMORY MAPPING APPENDIX BBMotor Mechanical Jam (Read/Write Grouped Setting)69B0 Mechanical Jam Function 0 to 1 --- 1 F102 0 (Disabled)69B1 Mechanical Jam Pickup 1 to 10 x FLA 0.01 F001 20069B2 Mechanical Jam Pickup Delay 0.1 to 600 s 0.01 F001 1069B3 Mechanical Jam Reset Delay 0 to 600 s 0.01 F001 069B4 Mechanical Jam Block 0 to 65535 --- 1 F300 069B5 Mechanical Jam Target 0 to 2 --- 1 F109 0 (Self-reset)69B6 Mechanical Jam Events 0 to 1 --- 1 F102 0 (Disabled)69B7 Reserved (9 items) --- --- --- F001 0Motor Learned Data (Read/Write Setting)69D0 Motor Learned Data Starts to Learn 1 to 5 --- 1 F001 169D1 Motor Learned Data Calculation Period 1 to 90 minutes 1 F001 1569D2 Reserved --- --- --- F001 0Motor Learned Data (Read Only Actual Values)69D3 Motor Learned Data Records Number 0 to 250 --- 1 F001 069D4 Motor Learned Data Last Cleared Date 0 to 4294967295 --- --- F050 069D6 Motor Learned Data Acceleration Time 0 to 655.35 s 0.01 F001 069D7 Motor Learned Data Starting Current 0 to 40 × FLA 0.01 F001 069D8 Motor Learned Data Thermal Capacity Used 0 to 65535 % 1 F001 069D9 Motor Learned Data Motor Load 0 to 40 × FLA 0.01 F001 069DA Motor Learned Data Run Time After Start 0 to 4294967295 hr 1 F050 069DC Reserved --- --- --- F001 0Phase Undervoltage (Read/Write Grouped Setting) (3 modules)7000 Phase Undervoltage 1 Function 0 to 1 --- 1 F102 0 (Disabled)7001 Phase Undervoltage 1 Signal Source 0 to 5 --- 1 F167 0 (SRC 1)7002 Phase Undervoltage 1 Pickup 0 to 3 pu 0.001 F001 10007003 Phase Undervoltage 1 Curve 0 to 1 --- 1 F111 0 (Definite Time)7004 Phase Undervoltage 1 Delay 0 to 600 s 0.01 F001 1007005 Phase Undervoltage 1 Minimum Voltage 0 to 3 pu 0.001 F001 1007006 Phase Undervoltage 1 Block 0 to 65535 --- 1 F300 07007 Phase Undervoltage 1 Target 0 to 2 --- 1 F109 0 (Self-reset)7008 Phase Undervoltage 1 Events 0 to 1 --- 1 F102 0 (Disabled)7009 Phase Undervoltage 1 Measurement Mode 0 to 1 --- 1 F186 0 (Phase to Ground)700A Reserved (6 items) 0 to 1 --- 1 F001 07013 ...Repeated for Phase Undervoltage 27020 ...Repeated for Phase Undervoltage 3Phase Overvoltage (Read/Write Grouped Setting)7040 Phase Overvoltage 1 Function 0 to 1 --- 1 F102 0 (Disabled)7041 Phase Overvoltage 1 Source 0 to 5 --- 1 F167 0 (SRC 1)7042 Phase Overvoltage 1 Pickup 0 to 3 pu 0.001 F001 10007043 Phase Overvoltage 1 Delay 0 to 600 s 0.01 F001 1007044 Phase Overvoltage 1 Reset Delay 0 to 600 s 0.01 F001 1007045 Phase Overvoltage 1 Block 0 to 65535 --- 1 F300 07046 Phase Overvoltage 1 Target 0 to 2 --- 1 F109 0 (Self-reset)7047 Phase Overvoltage 1 Events 0 to 1 --- 1 F102 0 (Disabled)7048 Reserved (8 items) 0 to 1 --- 1 F001 0Phase Directional Overcurrent (Read/Write Grouped Setting) (2 modules)7260 Phase Directional Overcurrent 1 Function 0 to 1 --- 1 F102 0 (Disabled)7261 Phase Directional Overcurrent 1 Source 0 to 5 --- 1 F167 0 (SRC 1)7262 Phase Directional Overcurrent 1 Block 0 to 65535 --- 1 F300 07263 Phase Directional Overcurrent 1 ECA 0 to 359 --- 1 F001 307264 Phase Directional Overcurrent 1 Pol V Threshold 0 to 3 pu 0.001 F001 7007265 Phase Directional Overcurrent 1 Block Overcurrent 0 to 1 --- 1 F126 0 (No)7266 Phase Directional Overcurrent 1 Target 0 to 2 --- 1 F109 0 (Self-reset)Table B–9: MODBUS MEMORY MAP (Sheet 27 of 59)ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT