Installation Preparation4Cabinet Preparation & Wire Routing• The wiring may enter the opening from either side,rear or the fl oor within the shaded area.• Cut a 1-1/2" max. dia. hole to admit the electrical cable.The hole must be free of sharp edges. If the cabinetwall is metal, the hole edge must be covered with abushing.• Cable direct connections may pass through the samehole as the drain hose and hot water line, if convenient.If cabinet wall is metal, the hole edge must be coveredwith a bushing. NOTE: Power cords with plug mustpass through a separate hole.Electrical Connection to DishwasherElectrical connection is on the right front of dishwasher.• For cable direct connections the cable must be routedas shown in Figure E. Cable must extend a minimum of24" from the rear wall.• For power cord connections, install a 3-prong groundingtype receptacle. The power-supply receptacle for theappliance shall be installed in a cabinet or on a walladjacent to the undercounter space in which theappliance is to be installed.Figure EWARNINGFOR PERSONAL SAFETY: Remove housefuse or open circuit breaker beforebeginning installation. Do not use anextension cord or adapter plug with thisappliance.PREPARE ELECTRICAL WIRINGElectrical Requirements• This appliance must be supplied with 120V, 60 Hz., andconnected to an individual properly grounded branchcircuit, protected by a 15 or 20 ampere circuit breakeror time delay fuse.• Wiring must be 2 wire with ground.• If the electrical supply does not meet the aboverequirements, call a licensed electrician beforeproceeding.Grounding Instructions – Cable DirectThis appliance must be connected to a grounded metal,permanent wiring system, or an equipment groundingconductor must be run with the circuit conductors andbe connected to the equipment grounding terminal orlead on the appliance.Grounding Instructions – Power Cord ModelsThis appliance must be grounded. In the event of a mal-function or breakdown, grounding will reduce the risk ofelectrical shock by providing a path of least resistancefor electric current. The plug must be plugged into anappropriate outlet that is installedand grounded in accordance with local codes andordinances.WARNINGThe improper connection of theequipment grounding conductor canresult in a risk of electric shock. Checkwith a qualifi ed electrician or servicerepresentative if you are in doubt thatthe appliance is properly grounded.White24"from Wall3"fromCabinetGroundBlack1-1/2" Dia.Hole (Max.)