GDL 82 Mooney M20( ) Series STC Installation Manual 190-01810-10Rev. 1Page 32 of 494.4.1 Shielded Cable Preparation1. At the end of the shielded cable, strip back 1.5 inch maximum length of the jacket to expose the braid.2. Remove the exposed braid.3. Score the jacket 1/4 inches to 5/16 inches from the end and remove the jacket to leave the braidexposed.4. Connected a 20 or 22 AWG wire to the exposed braid of the prepared cable using one of the belowmethods. For termination techniques, refer to AC 43.13.PREFERED METHODSlide a solder sleeve (1) onto the prepared cable and shrink using heat gun. The chosen size ofsolder sleeve must accommodate the number of conductors present in the cable assembly. Refer toTable 4-2 for materials; use M83519/2-2 for 2-conductor and M83519/2-3 for 3-conductor soldersleeve. Solder sleeves with preinstalled leads are acceptable.ALTERNATE METHODSolder an insulated (20-22AWG; 3 inch maximum length) wire (2) to the exposed braid of theprepared cable. Slide a piece of shrink tube (1) onto the prepared cable and shrink using a heat gun.The chosen size of shrink tube must accommodate the number of conductors present in the cable.Figure 4-8: Shield Termination5. Repeat steps 1 through 4 as needed for the remaining shielded cables.