GDL 82 Mooney M20( ) Series STC Installation Manual 190-01810-10Rev. 1Page 34 of 494.4.3 Wiring Harness RoutingRoute wire harness from the 15 pin D-sub (J821) on the GDL 82 unit to existing aircraft wire harness.Breakout the USB dongle cable wiring and secure near the GDL 82 unit. Continue routing wiring alongexisting harness to instrument panel/CB console. Terminate all wiring as shown in wiring diagram(Figure 4-7).If the existing coaxial cable meets the minimum requirements in Section 3.4, then no change is requiredin coaxial cable routing. If new coaxial cable is required:1. Route coaxial cable from XPDR (J823) connection on the GDL 82 unit to existing A/C wireharness, using existing clamping stations, to the existing transponder.2. Route coaxial cable from ANT (J824) connection on the GDL 82 unit to existing A/C wireharness, using existing clamping stations, to the existing L-band antenna.3. If required, route GPS coaxial cable from the GPS (J822) connection on the GDL 82 unit to theGPS antenna in accordance with the specifications in Section 3.4.2.NOTES1 THE DIRECT CONNECTION TO A GPS ANTENNA IS ONLY AVAILABLE WITH THE GDL 82 WITH INTERNAL GPS. GPS SOURCE DATA CANALSO BE PROVIDED VIA RS-232 FROM AN APPROVED EXISTING GARMIN NAVIGATOR. SEE SECTION 1.2 FOR APPROVED EXTERNAL GPSSOURCES.2 EXISTING TRANSPONDER TRANSMISSION COAXIAL CABLE NEEDS TO BE MODIFIED TO ALLOW FOR INSTALLATION OF THE GDL 82UNIT IN SERIES BETWEEN THE EXISTING TRANSONDER AND THE L-BAND ANTENNA. SEE SECTION 3.4 FOR COAXIAL CABLESPECIFICATIONS.Figure 4-10: Option 1 Wire Harness Routing Example