Appendix A - Certification DataA-2 560-1049-00 Rev B GDL 90 Installation ManualA.2 MICRO APM ENVIRONMENTAL QUALIFICATIONThe Micro APM has been tested with the GDL 90 to the following environmental categories per procedures definedin RTCA/DO-160D. Tests were conducted in February to April 2004 using the original 1997 revision of DO-160Dand the specification defined in PD3536.Environmental Qualification FormNomenclature: Micro APMPart No.: 430-6200-xxxTSO No.: C154Manufacturer:Garmin AT2345 Turner Road SESalem, Oregon 97302Environment Section Category CommentTemperature and Altitude 4 F1 & A1 Operating temp ........ –20°C to +55°CShort time hi temp .... to +70°CGround survival temp –55°C to +85°CAltitude .................... 55,000 feetDecompression 55,000 feetOverpressureLoss of cooling test -- not requiredTemperature Variation 5 B Minimum 5°C per minuteHumidity 6 B Severe humidity environment.Operational Shocks and CrashSafety7 B5R meets operational and crash safety shock tests 20Gs at 11 ms.Vibration 8 S(M & B) Standard vibration. Meets without shock mounts.Explosion Proofness 9 X not applicable, no test requiredWaterproofness 10 X not applicable, no test requiredFluids Susceptibility 11 X not applicable, no test requiredSand and Dust 12 X not applicable, no test requiredFungus Resistance 13 X not applicable, no test requiredSalt Spray 14 X not applicable, no test requiredMagnetic Effect 15 Z < 0.3 meterPower Input 16 A & B [1] for 28 and 14 volt systemsVoltage Spike 17 A [1]Audio Frequency ConductedSusceptibility - Power Inputs18 Z [1]Induced Signal Susceptibility 19 CRadio Frequency Susceptibility(Radiated and Conducted)20 UV- Equipment tested to Category U (Conducted)Equipment tested to Category V (Radiated)No Pulse tests performed.Emission of Radio FrequencyEnergy21 M [2]Lightning Induced TransientSusceptibility22 XXXX [2] not applicable, no test requiredLightning Direct Effects 23 X not applicable, no test requiredIcing 24 X not applicable, no test requiredElectrostatic Discharge (ESD) 25 A[1] APM powered by GDL 90. APM not directly exposed to this condition.[2] Maximum APM wire length 4 inches.