15MAINTENANCE & ADJUSTMENTSG. Adjustment GuidesForce SettingsForce settings are pre-programmed at the factory and appliedduring the Open/Closed Limit settings steps. For normal use, thesesettings should not need adjustments with this unit.H. Resetting Travel LimitsSee pages 8-9 to reset travel limits. Force setting and contact reverse test must be performed in the event of a travel limit change.AVERTISSEMENT!Pour éviter les blessures ou des dommages• NE JAMAIS régler la force pour compenser des dommages,y compris une porte mal équilibrée, un rail de porte coinçantou des ressorts cassés.• Tous les mois, EFFECTUEZ LE TEST D’INVERSION AU CONTACT.Voir page 10.WARNING!TO AVOID INJURY OR DAMAGE• NEVER adjust the force settings to adjust for damage,including an unbalanced door, binding door track orbroken spring.• Perform a CONTACT REVERSE TEST monthly. See page 10.Conditions possibly requiring adjustments are:1. Doors with very stiff weather seals.2. Doors that start down, STOP, and reverse before closing.3. Doors that start up, but STOP before they completely open.Press and hold both up anddown arrow buttons untilround LED turns RED, releasebuttons. Round BLUE LED willflash 3 times.LEDs will now display current UP force setting (See chart).Press either arrow button untildesired UP force setting isreached.See ChartOnce setting is chosen, pressand release. This will lock theUP force setting.LEDs will now show current DOWN force setting. (See Chart).Press either arrow button untildesired DOWN force setting isreached.See ChartOnce setting is chosen, pressand release. This will lock theDOWN force setting.The LEDs will now turn BLUE then off. This confirmsthat both force settings have been set and unit isready for normal operation.Repeat “Learn Force Limits and Contact Reverse Test” page 10.OFFBLUEBLUEOFFFlashes3 TimesOFF REDBLUEPRGMSETPRGMSET