5.8Figure 11WARNING: Actuating the operator using constant contact on the CLOSEbutton will override external reversing devices, including photocells andreversing edges.SENSING EDGE SWITCHSENSING EDGE SWITCHTERMINAL STRIPFigure 10BNOTE::2-wire monitoredsensing edge switchmust be connectedthrough the MillerEdgeInterface Module SM-101.NOTE Monitored 2-wiresensing or reversingedge can also be usedin combination with aTimer-Close Module.TIMER-CLOSE MODULE TERMINAL STRIPSENSING EDGE SWITCHN-OREVERSE N-OREVERSEFigure 10ANOTE Non-monitoredsensing edge can beconnected directly tothese terminals. DO NOTconnect a 2-wire Monitoredsensing edge switch tothese terminals.CONTROL SIGNALTERMINAL STRIPCONTROL SIGNALGNDMONEDGEINTERFACE MODULEwww.geniecompany.com 0-12Standard Duty OperatorGCL-J&HFigure 11 shows an example of a typical sensing edge installation. Left hand side is shown butright hand is a mirror image of this.1A) If wiring from sensing edge switch to operator is coiled cord or 2 wire jacketed cord:• Install junction box 12” above the center of the door opening on same side assensing switch.• Secure one end of cord to junction box using a cable clamp.1B) If connection is to be made through a take up reel cord:• Install on same side as sensing edge switch and above door opening andslightly to the side.• Install junction box adjacent to take up reel and route the stationary cord fromthe reel to the box and secure with a cable clamp.2) Secure other end of cord (straight, coiled or reel) to sensing edge switchenclosure using a cable clamp.3) Connect wires of cord to sensing edge switch using wire nuts or other suitablewire connectors.4) Run a straight 2 wire cord from the junction box (Step 1) to the operatorelectrical box.• Secure using cable clamp on each end.5) Join wires in cord from operator to wires in cord from switch using wire nuts orother suitable wire connectors.6A) Non-Monitored sensing or reversing edge connects to terminal strip on main boardeeS.stupniesrevergnisu A01.giF .6B) Monitored sensing or reversing edge connects to Timer-Close Module terminalsor to terminal strip on main board through OPAKMEIX.S as shown in Fig. 10B.7) Operate the door to make certain cord is free to travel and does not becomesnared during door opening or closing.• Check sensing edge switch for proper operation.Sensing Edge Switch InstallationODCSTB ODCSTBNOTE: Do not use a take-up-reel on a monitored edge. They have slip connections in themthat momentarily break contact which causes false reversals.