6.1OPENCLOSESTOPCALRUN SCROLLSCROLLSETCLEARSection 6: Operator Setup ProcedureOperators include a full function control panel including a liquid crystaldisplay (LCD), calibration keys and Open, Close and Stop keys for on boardoperator control. See Fig. 1. The open, close and stop keys function as a 3-buttonwall control. The Display will show current operator conditions and calibrationinformation. Due to limited character space, some displays will be abbreviated.See Appendix C (pgs. 10.9-10.11) for full display descriptions.Operators include a non-volatile memory. The unit will remember allcalibration settings plus error code and run code logs, if power is removed fromunit.DANGER: After power is supplied to the operator, Do Not makecontact with components inside the control panel except for the KeypadKeys. Fig. 1.Control Operating ModesOperator control boards operate in two modes: Run Mode and CalibrationMode. The control board should normally operate in the Run Mode. The operatoris calibrated in Calibration Mode.With the operator standing idle:PRESS CAL/RUN TO TOGGLE BETWEEN OPERATING MODES.• The first display in calibration mode is “SET CLOSE DIRECTION”• The display in run mode will be one of the condition codes listedin Appendix C.Control PanelOperation Keys, operateunit like a 3-buttonwall station.Scroll Keys, used inCalibration Mode.Set/Clear Key, used toreset and adjustcalibration settings.Figure 1Calibration & RunMode Toggle Key.Display BacklightingToggle Key.LCD DISPLAYWARNING: DO NOT calibrate operator or operate door unlessdoorway is in sight and free of obstructions. Keep people clear ofopening while door is moving.www.geniecompany.com -12Standard Duty OperatorGCL-J&H