TypeMountingMax.DoorWeight(Lbs)16GA.FlushSteel16GA.FlushSteelInsulated20GA.RibbedSteel20GA.RibbedSteelInsulated24GA.RibbedSteel24GA.RibbedSteelInsulatedNominal24GA.RibbedSteelNominal24GA.Ribbed SteelInsulatedInsulatedPU/FIPInsulatedPU/FIP1.38"1/8" Glass1.38" Glass1.38"InsulatedPU/FIP2"InsulatedPU/FIP2"20GA.Y es TSC 1120 256 220 370 256 440 340 320 320 256 360 400 300 400 380 360 240TSC 1370 330 256 440 310 530 400 320 320 256 450 450 370 460 440 400 330TSC 1620 380 280 500 370 570 410 320 320 256 480 480 420 500 480 400 400Y esY esS=Jackshaft,SideMount C=Jackshaft,CenterMountUL L is tedHPModelT=TrolleyAluminumDoor S eries ->Section 3: Critical Installation Information3.3Note: Total door weight, and not the square footage, is the critical factor in selecting the proper operator.Square footage measurements are based on "square doors." (Example=16' x 16')NOTE: Doors that require special windloading and wide doors, normally require increased strutting (reinforcement). Strutting doors can significantly increase doorweight beyond weight shown. Consult Customer Service for the impact of wind load andstrutting on square foot limits.NOTE: "PU-FIP" stands for "polyurethane, foamed-in-place." If no notation is present, insulation is "polystyrene, layed-iin-place."IMPORTANT INSTALLATION INSTRUCTIONSWARNING -To reduce the risk of severe injury or death:1) READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS.2) Install only on a properly operating and balanced door. A door that is operatingimproperly could cause severe injury. Have qualified service personnel makerepairs to cables, spring assemblies and other hardware before installing the operator.3) Remove all pull ropes and remove, or make inoperative, all locks (unless mechanicallyand/or electronically interlocked to the power unit) that are connected to the doorbefore installing the operator.4) Install door operator at least 8 feet above floor if operator has exposed moving parts.5) Do not connect the door operator to the power source until instructed to do so.6) Locate the control station: (a) within sight of door, (b) a minimum of 5 feet abovefloor so that small children cannot reach it, and (c) away from all moving parts of door.7) Install the Entrapment Warning Placard next to the control station and in aprominent location.8) For products having a manual release, instruct the end user on the operation of themanual release.Sectional Door Chart (sq. ft.)GCL-J&H 1/2GCL-J&H 3/4GCL-J&H 1www.geniecompany.com 0-12Standard Duty OperatorGCL-J&H216 216 ins. 220 220 ins. 2415 2415 ins. 2411 2411 ins. 125 150 200 200-20 5150 5200 451 452CommercialSteelInsulated&Non-Insulated Thermospan ThermomarkExteriorInsulatedPU/FIPRaisedPanel1.38"Insulated 1/4" or 1/2"PU/FIPRaisedPanel2"