1) For a single 3 - button installation, make connections asshown in Fig. 3.2) For single button accessory controls, make connections asshown in Fig. 4.3) For a multiple 3 - button installations, make connections asshown in Fig. 5.NOTE: If an External STOP button is NOT being installed, a jumper wiremust be installed between the “STOP” AND “GND” terminals as shown.NOTE: Long Distance Relay Kit wiring is not required for longdistance control runs and should not be used5.4Wall ControlWARNING:• Wall Control(s) must be located so that the door is within sight ofthe user and is far enough from the door, or positioned such thatthe user is prevented from coming in contact with the door whileoperating the controls .• Attach the Warning placard adjacent to the Wall Control. Fig. 3A.WARNING:If momentary contact control is to be used, an external reversing device suchas a photocell system or sensing edge switch must be used. See pages5.6-5.7 for installation of entrapment protection devices.NOTE:JUMPER BETWEENSTOP AND GNDTERM NALS MUSTBE REMOVED3-BUTTONSTAT ONCONTROL SIGNAL TERMINAL STRIPOPEN CLOSE STOP GND3-BUTTONSTAT ONOPENCLOSESTOPOPENCLOSESTOPFigure 41-BTNSTAT ONKEYSW TCHSTAT ONCARDREADEROPEN/CLOSEPULL SW TCHCONTROL SIGNAL TERMINAL STRIPODCSTBGNDSTOP 1-BTNFigure 5OPENCLOSESTOP3-BUTTONSTAT ONCONTROL SIGNAL TERMINAL STRIPNOTE:JUMPER BETWEENSTOP AND GNDTERMINALS MUSTBE REMOVEDOPEN CLOSE STOP GNDFigure 311 735EntrapmentWarningPlacardFigure 3Awww.geniecompany.com 06-12Standard Duty OperatorGCL-T