6.4OPENCLOSESTOPCALRUN SCROLLSCROLLSETCLEARSetting Travel LimitsUP LIMIT SETFigure 7OPENCLOSESTOPCALRUN SCROLLSCROLLSETCLEARDOWN LIMIT SETFigure 8NOTE: The recommended setpoint for the DOWN Travel Limit is normally atapproximately 2 inches off the floor. This final distance will be covered by the LimitOverrun Function to establish a more accurate seal.CALRUNSCROLLSETCLEAROPENSCROLLCALRUNCLOSECLOSEResetting Travel LimitsCALRUNCROLOPENSETCLEARCALRUNSETCLEARUP and/or DOWN1) If operator is in RUN mode, press CAL/RUN to enter calibration mode.2) Press SCROLL until display reads “UP LIMIT>CLR ” or“DOWN LIMIT>CLR ” Figure 7.3) Jog the door using the OPEN or CLOSE key until you reach thedesired height.4) Press SET/CLEAR key to switch display to “UP LIMIT>SET “ or“DOWN LIMIT>SET .“ Figure 8.5) Press a SCROLL key to shift to a new function and lock in thelimit setting.limit setting.SCROLL6) Press a SCROLL key to shift to a new function and lock in the6) Press CAL/RUN to return to run mode.UP and/or DOWN1) If operator is in RUN mode, press CAL/RUN to enter calibration mode.2) Press SCROLL until display reads “UP LIMIT>SET ” or“DOWN LIMIT>SET.” Figure 8.3) Press SET/CLEAR to switch display to ”UP LIMIT>CLR” or”DOWN LIMIT>CLR”4) Jog the door using the OPEN or CLOSE key until you reach the5) Press SET/CLEAR to switch display to ”UP LIMIT>SET” or”DOWN LIMIT>SET”7) Press CAL/RUN to return to runwww.geniecompany.com 06-12Standard Duty OperatorGCL-T