CAUTIONWARNINGWall consoleWall buttonORFig. 4-2#6 x 1”pan head screwsFig. 4-3MORETMENTOPENPUSHLIMITSTO SETG4Y3B2W11. Run wire from power head to wall control.• Place the wall control:– In sight of door.– At least 5 feet from floor, so small children cannot reach it.– Away from moving parts of door anddoor hardware.• Use staples to fasten wire to ceiling and wall.2. Remove 1/2” insulation from each wire(Fig. 3-6)(pg. 19).3. Attach wires to terminals (Stealth Fig. 4-1a)(MAX Fig. 4-1b).• Loosen, but Do Not remove screw from terminal.For Stealth.– Connect striped wires to terminal “2” on powerhead and “B” on wall control.– Connect white wire to terminal “1” on powerhead and “W” on wall control.For MAX.– Connect striped wires to terminal “1” on powerhead and “B” on wall control.– Connect white wire to terminal “2” on powerhead and “W” on wall control.4. Mount wall control (Fig. 4-2).• Use two pan head screws.5. Mount entrapment warning label.• Remove protective backing and stick nearwall control.• Use tacks or staples to permanently mount Label.• Make sure everyone reads and follows WARNINGS.NOTE: Additional wall controls are available from yourdealer. ONLY ONE OF YOUR WALL CONTROLS MAY BE THELIGHTED TYPE. If you have a lighted wall control, all youradditional controls must be un-lighted. More than onelighted wall control per operator will cause a malfunction.Power cord must be unplugged before attachingwires. Be sure wire ends do not touch each otheror other terminals.• Use of any other wall control will cause thelight not to work and could cause door tooperate by surprise.• Cut or pinched wires can cause door operatorto malfunction. Drive staples just tight enoughto hold wire.Fig. 4-1a1234WBB WWhiteStripedWallconsoleterminalsWallbuttonterminalsPower headterminalsBack viewBack view1234WhiteStripedORPowerheadferminalsRear view ofpower headFig. 4-1bNECCLASS 2123456MOREFORCEPUSHBUTTONSAFETYBEAMLIMITSETOPENFORCECLOSEFORCERADIOSIGNALLEARNCODECOMDO NOTPUSHLIMIT SETUNLESSDOOR ISATTACHEDNOTE:USE ONLY WITHSERIES II CONTROLSCLOSEMOREOPENMOREOSE OPENLIMIT ADJUSTMENTU.S. Patent No. 5,243,7845,221,869C SS123WBB WStripedWhiteWallconsoleterminalsWallbuttonterminalsPower headterminalspower headterminalsBack viewBack viewFront view ofpower headC SS123StripedWhiteEITHER204 ... WALL CONTROL INSTALLATION FOR HELP-1.800.354.3643 OR GENIECOMPANY.COMIndependent Light Control– Controls door operator lights from inside garage– Energy-Saver shut-off turns off light 5 minutes afterdoor activationVacation Locking Switch– LOCK disables controls after door is completely closed– UNLOCK allows controls to work normallyLighted Button– Shows system is powered– Lights when Security LockSwitch is in UNLOCK position– Goes out when Security LockSwitch is in LOCK positionDoor Control Button– Open and closes door frominside garage1432