Section 4 • Repair ProceduresREV BNovember 20054 - 8 GR-12 • GR-15 • GR-20 Part No. 847001-3Software ConfigurationThe Electronic Control Module (ECM) containsprogramming for all configurations of the GenieRunabout. The machine can be adjusted to adifferent configuration using the buttons at theplatform controls.How to Determine theSoftware Configuration1 Remove the platform controls from the platform.2 Turn the key switch to platform control and pullout the red Emergency Stop button to the onposition at both the ground and platformcontrols.Result: The diagnostic display at the platformcontrols will show the battery condition. See1-3, How to Determine the Battery Voltage.3 Press the lift function select button.4 Slowly move the joystick in the directionindicated by the blue arrow.Result: The machine configuration code willappear in the diagnostic display.5 Push in the red Emergency Stop button to theoff position at both the ground and platformcontrols and turn the key switch to the offposition.PLATFORM CONTROLSabdecfa joystick controller JC1 with thumbsteering rocker SW6b lift function select button BN9c diagnostic displayd red Emergency Stop button P2e drive function select button BN8f blue arrow