24SECT 4—WALL CONTROL INSTALLATION FOR HELP- 1.800.354.3643Fig. 4-11. Run wire from power head to wall control• Find location for wall control:– In sight of door and away from moving parts.– At least 5 feet from floor, so smallchildren cannot reach it.• Route wire from wall control to power head.• Use staples to fasten wire to ceiling and wall.NOTE: Use only staples included2. Split wires at ends and remove 1/2 inch ofinsulation from end of each Wire. Fig. 4-1.3. Attach wires to terminals. Fig. 4-2, Fig. 4-3.• Loosen (Do Not Remove) screws fromTerminals at power head and wall control• Connect wires to power head– White wire to terminal # 1– Striped wire to terminal #2– Tighten screws• Connect wires to wall control– Striped wire to terminal “B”– White wire to terminal “W”– Tighten screws4. Mount wall control. Fig. 4-4.• For Wall Console or Wall Button.– Use pan head screws [34].5. Mount entrapment warning label. Fig. 4-4.• Remove protective backing.• Stick label to wall next to wall control.– Tacks or staples may be required on somerough texture surfaces.NOTE: Additional wall controls are available fromyour dealer. ONLY ONE OF YOUR WALL CONTROLSMAY BE THE LIGHTED TYPE. If you have a lightedwall control, all your additional controls must beun-lighted. More than one lighted wall control peroperator will cause a malfunction.Power must be removed before attaching wires.Be sure ends do not touch each other or otherterminals.WARNING• Use of any other wall control can cause thedoor to operate unexpectedly and the lightnot to work.• Cut or pinched wires can cause dooroperator to malfunction. Drive staples justtight enough to hold wire.CAUTION1/2"1-1/4” to 1-1/2"Fig. 4-2button consoleFig. 4-3Fig. 4-4#6 x 1-1/4" Pan head screw[34]