First Edition • Second Printing Operator's ManualWork Area SafetyPart No. 1272873GT Z ® -62/40 TRAX™ 13Work Ar ea SafetyPictures in this manual may show a boom with tiresand wheels instead of tracks. All safety informationand operating instructions still apply to the Z-62/40TRAX, even if the picture does not show the tracks.Electrocution HazardsThis machine is not electrically insulated and willnot provide protection from contact with orproximity to electrical current.Obey all local andgovernmental regulationsregarding requiredclearance from electricalpower lines. At a minimum,the required clearancecontained in the chart belowmust be followed.Line Voltage Required Clearance0 to 50KV 10 ft 3.05 m50 to 200KV 15 ft 4.60 m200 to 350KV 20 ft 6.10 m350 to 500KV 25 ft 7.62 m500 to 750KV 35 ft 10.67 m750 to 1000KV 45 ft 13.72 mAllow for platform movement, electrical line sway orsag, and beware of strong or gusty winds.Keep away from themachine if it contactsenergized power lines.Personnel on the groundor in the platform must nottouch or operate themachine until energizedpower lines are shut off.Do not operate the machine during lightning orstorms.Do not use the machine as a ground for welding.Tip-over HazardsOccupants, equipment and materials shall notexceed the maximum platform capacity or themaximum platform capacity of the platformextension.Maximum platform capacity 500 lbs 227 kgMaximum occupants 2The weight of options and accessories, such aspipe cradles, panel cradles and welders, willreduce the rated platform capacity and must besubtracted from the platform capacity. See thedecals with the options and accessories.If using accessories, read, understand and obeythe decals, instructions and manuals with theaccessory.