Installation ManualH3C S5600 Series Ethernet Switches Chapter 3 Installing the Switch3-19II. RemovingStep 1: Wear an ESD wrist strip which is well grounded.Step 2: Use the Phillips screwdriver to unscrew the captive screws at both sides of themodule.Step 3: Pull the module towards you until it is completely apart from the chassis bottom.Caution:When installing/removing an optional interface module, note that:z Do not exert excessive strength on the module or touch the components on themodule surface.z Install a blank filler panel, if you do not want to install a new module right after the oldone is removed, to keep the dust out and ensure the normal ventilation of the switch.3.8 Verifying Installationz The correct power source is used.z The ground wire is securely connected.z Both of the console cable and power cord are correctly connected.z All the interface cables are routed indoors. If there are cables outdoors, check thatthe socket strip with lightning protection and lightning arresters for network portshave been correctly connected.