65In IRF mode:Slot No. Brd Type Brd Status Subslot Num Sft Ver1/0 NONE Absent 0 NONE1/1 LST1MRPNC1 Master 0 S12500-CMW520-A12211/2 NONE Absent 0 NONE1/3 NONE Absent 0 NONE1/4 NONE Absent 0 NONE1/5 LST1GT48LEC1 Normal 0 S12500-CMW520-A12211/6 NONE Absent 0 NONE1/7 NONE Absent 0 NONE1/8 NONE Absent 0 NONE1/9 NONE Absent 0 NONE1/10 NONE Absent 0 NONE1/11 NONE Absent 0 NONE1/12 NONE Absent 0 NONE1/13 NONE Absent 0 NONE1/14 NONE Absent 0 NONE1/15 LST1SF08B1 Normal 0 S12500-CMW520-A12211/16 NONE Absent 0 NONE1/17 NONE Absent 0 NONE1/18 NONE Absent 0 NONETable 17 display device command output descriptionField DescriptionSlot No. Slot number of a card (standalone mode); slot number of a card on the specifiedmember switch in the format of member ID/slot number (IRF mode)Brd TypeHardware type of a card, which can be:• Specific card model, such as LST1MRPNC1, which is the same as the silkscreen.• NONE: No card is in the slot.• UNKNOWN: The card is not supported by the software version and thus cannotstart normally.Brd StatusCard status, which can be:• Absent: No card is in the slot.• Master: The card is an active main board (AMB).• Slave: The card is a standby main board (SMB).• Normal: The card is an interface card and operates normally.• Fault: The card in the slot has not started or fails.• Off: The card is not powered on.• Illegal: The card is not supported by the software version and thus cannot startnormally.Subslot Num Number of subcardsSft VerSoftware version of the current card, which can be:• Specific software version: The software version of the switch.• NONE: No card is in the slot.• Mismatched: The software version does not support the card and thus cannot beuploaded.