Command Manual – System Maintenance and DebuggingH3C S7500 Series Ethernet Switches Chapter 3 Device Management Commands3-18After you execute the command, the system will prompt you to confirm. Enter "Y" or "y"for your setting to take effect. Your setting will overwrite the old one (if available).If you adjust the system time by the clock command after executing the schedulereboot delay command, the schedule reboot delay command will be invalid and thescheduled reboot will not happen.Related commands: reboot, schedule reboot at, undo schedule reboot, displayschedule reboot.Examples# Suppose the current time is 16:26, schedule a reboot so that the switch reboots after88 minutes. schedule reboot delay 88Reboot system at 17:54 2005/04/06(in 1 hours and 28 minutes)confirm?[Y/N]:y%Apr 6 16:26:38 2005 S7506R CMD/5/REBOOT:aux0: schedule reboot parameters at 16:26:34 2005/04/06. And system will rebootat 17:54:2005 04/06/2005.3.1.24 temperature-limitSyntaxtemperature-limit slot-number down-value up-valueundo temperature-limit slot-numberViewUser viewParametersslot-number: Physical card slot number.down-value: Lower temperature limit, ranging from 0 to 70, in centigrade.up-value: Upper temperature limit, in centigrade, ranging from 20 to 90, and must begreater than the down-value.DescriptionUse the temperature-limit command to configure temperature alarm threshold.Use the undo temperature-limit command to restore temperature alarm threshold tothe default.By default, the lower temperature limit is 20, and the upper limit is 80.