Operation Manual – MSTPH3C S7500 Series Ethernet Switches Chapter 1 MSTP Configuration1-43 system-view[H3C] stp region-configuration# Configure the MST region.[H3C-mst-region] region-name example[H3C-mst-region] instance 1 vlan 10[H3C-mst-region] instance 3 vlan 30[H3C-mst-region] instance 4 vlan 40[H3C-mst-region] revision-level 0# Activate the settings of the MST region.[H3C-mst-region] active region-configuration# Specify Switch C as the root bridge of MSTI 4.[H3C] stp instance 4 root primary4) Configure Switch D.# Enter MST region view. system-view[H3C] stp region-configuration# Configure the MST region.[H3C-mst-region] region-name example[H3C-mst-region] instance 1 vlan 10[H3C-mst-region] instance 3 vlan 30[H3C-mst-region] instance 4 vlan 40[H3C-mst-region] revision-level 0# Activate the settings of the MST region.[H3C-mst-region] active region-configuration1.11 VLAN-VPN Tunnel Configuration ExampleI. Network requirementsz S7500 series switches operate as the access devices of the operator’s network,that is, Switch C and Switch D in the network diagram.z S3100 series switches operate as the access devices of the user’s network, that is,Switch A and Switch B in the network diagram.z Switch C and Switch D connect to each other through the configured trunk port ofthe switch, and are enabled with the VLAN-VPN function. Thereby transparenttransmission is realized between the user’s network and the operator’s network.