23Installation of Outdoor UnitSelection of installation placePlace strong enough to support unit weight, and will not cause vibration and noise.Place where discharged wind and noise do not cause nuisance to the neighbors, and is sufficientlyventilated.Place where is less affected by rain or direct sunlight and sea breeze.Place with enough space for smooth air flow.The unit cannot be installed on an unspecified metal frame (e.g. theft guard net).It shall be not less than 2.5m high from the ground if the outdoor unit is installed close to a street.Easy for maintenance.Fixing the unitFix outdoor unit bracket to the wall using anchor bolt (M10).Fasten the outdoor unit onto the installation bracket with bolt (M10) and nut ,and keep it horizontal.If installation on the wall or on top of a roof, bracket shoukd be fixed securely to resist earthquake orstorms.Be sure to use rubber pad during installation against unit vibration.Install the unit in such a way that the angle of inclination is lees than 3 degrees.Installation dimension of outdoor unit (mm)140 500 140256Note :(1). Fix the parts with screws(2).Don't intake the strong wind directly to theoutlet air-flow hole.(3).A one meter distance should be kept from theunit top(4).Don't block the surroundings of the unit withsundriesInstallation ProceduresL2L3L1500(Servicingspace)Air outletAir inletAirinletOpen space requirement around the unit