All electrical repairs must be carriedout by qualified electricians. Inadequaterepairs may result in a major source ofdanger for the user of the airconditoiner.Do not damage any parts of the airconditioner that carry refrigerant bypiercing or perforating the airconditioner's tubes with sharp orpointed items, crushing or twisting anytubes, or scraping the coatings off thesurfaces. If the refrigerant spurts outand gets into eyes, it may result inserious eye injuries.Do not obstruct or cover theventilation grille of the air conditioner.Do not put fingers or any other thingsinto the inlet/outlet and swing louver.Do not allow children to play with theair conditioner. In no case shouldchildren be allowed to sit on theoutdoor unit.SpecificationsThe refrigerating circuit is leak-proof.1. Applicable ambient temperature range:The machine is adaptive in followingsituationCoolingIndoor Maximum:Minimum:D.B / W.BD.B /D.BOutdoor Maximum:Minimum:D.B 43 C/ 26 C15 C18 C/ 14 C32 C/ 23 CCautionsOther Instructions*2. If the supply cord is damaged, it must bereplaced by the manufacturer or its serviceagent or a similar qualified person.3. If the fuse on PC board is broken pleasechange it with the type of T 3.15A /250VAC.4.Use copper wire only. The connecting cableshould be H05RN-F4G(3X2.5+1X0.75)mm22********The power cable should be H05RN-F 3G 2.5mm.5. The wiring method should be in line withthe local standard.All the cables shall havegot the European authentication certificate.6. The air breaker should be all-pole switch.and the distance between it's twoconnecters should no less than 3mm.7. Air conditioner must use special power supplysystem (above 20A), and qualified electricianmakes wiring and fixing according to wiringregulations specified in national standard.8. In socket, exactly distinguish earth wire withneutral wire and it is wrong to connect themtogether.9. A leakage breaker must be installed.10. Connection method is Y-connection .If thepower cord is damaged, it must be replacedby professional people of manufacturer or itsmaintenance department or similar to avoiddangers.11. The air breaker and the power switch shouldinstalled the conveniently reachable place foruser.Attention:As a result of poor conditions of the electricalMAINS, shortly voltage drops can appearwhen starting the EQUIPMENT. This caninfluence other equipment (et.Blinking of alamp). If the MAIN-IMPEDANCE Zmax< 0.4624277HM, such disturbance are notexpected. In case of need , you may contactyour local supply authority for furtherinformation.Attention:1. The waste battery shall be disposed properly.Whenthrow away the waste batteries, please perform inaccordance with the local regulation.2. The indoor unit installation height is at least 2.5m.certificate.