17Installation Manual of Room Air ConditionerPlace where it is easy to route drainage pipeand outdoor piping.Place ,away from heat source and with lessdirect sunlight.Place where cool and warm air could bedelivered evently to every corner of the room.Place near power supply socket.Leave enoughspace around the unit.Place ,robust not causing vibration,where thebody can be supported sufficiently.To prevent interference, place it at least 1maway from other electric machines, such asTV set, radio.InstallingAccording to the dimension of the figure 2 shown,nail two cement steel nails on the wall,Keep 2~3mm out.then hang the back of the unit on them.There must be no gap between the indoor unitand wall.Remove the front panel,then use two expansiblescrews to fix the unit on the floor.As figure 3shown.Once refrigerant piping and drain piping connectionsare complete,fill the gap of the throght hole with putty.Attach the front panel and front grille in their orginalpositions once all connections are complete.Tool necessary1. Screw driver2. Hacksaw3. 70mm dia.hole core drill4. Spanner(dia. 17,27mm)5. Spanner(14,17,27mm)6. Pipe cutter7. Flaring tool8. Knife9. Nipper10. Gas leakage detector or soap water11. Measuring tape12. Reamer13. Refrigerant oilStandard accessoriesFollowing parts shall be field suppliedInstallation of indoor unitselection of installation placeFig1Mark Part nameAdhensive tapePipe clipConnecting hoseInsulation materialPuttyDrain hoseABCDEF330617Fig2Fig3more thanmore thanmore thanmore than