Haier AW09ES2VHB Service Manual
Also see for 1U09AP2VHA: Installation manual
Contents |
SEQUENCE OF OPERATIONPAGE 23ENGLISHThe outdoor unit main board also controls the position ofthe EEV (Electronic Expansion Valve) to regulate the flow ofrefrigerant to the indoor unit evaporator coil.Temperature SensorsFour temperature sensors located in the outdoor unit providetemperature information to the outdoor unit main board forcontrol of the system during cool mode.The outdoor ambient temperature sensor provides the tem-perature of the air drawn into the outdoor coil of the outdoorunit.The defrost temperature sensor provides the temperaturesensed at the output of the outdoor coil.The suction line temperature sensor provides the tempera-ture sensed at the incoming suction line pipe.The compressor discharge sensor provides the temperaturesensed at the discharge pipe of the compressor.Call to Terminate CoolingThe system will call to terminate cooling when the indoor am-bient temperature sensor is equal to or lower than 2°F of theroom set temperature. The indoor control board will com-municate to the outdoor control board to de-energize thecompressor. The outdoor fan will run for 60 seconds beforestopping.The indoor fan motor and louver will continue operating aftercooling has been terminated.To stop cool mode, press the power button to turn the sys-tem off, or change to another mode.Freeze Protection FunctionTo prevent freezing of the indoor unit coil during cool mode,when the compressor operates continuously for 10 secondsand the temperature of the indoor coil has been below 32°Ffor 10 seconds, the compressor will stop, and the error willbe recorded in the malfunction list. The indoor unit fan willcontinue to operate. When the temperature of the indoor coilrises to 45°F for more than 3 minutes the compressor willrestart and the system will continue functioning.Heat ModeOverviewThe setpoint control range in heating mode is 60°F - 86°F. Thetemperature set by the remote control and the indoor unitambient temperature sensor will determine if a call for heat isneeded. If a call for heat is justified, a temperature compen-sation adjustment is automatically added to the operatingparameter and the call is communicated from the indoor unitto the outdoor unit.The indoor unit louver will open using a stepper motor. Theindoor fan will not operate at this time.The outdoor unit will shift the 4-way valve to the heat modeposition and determine the position of the EEV (if equipped)and speed (frequency) of the compressor. There can be adelay of up to 3 minutes before the outdoor unit fan and com-pressor start.(Tr = room temperature Ts = set temperature)If Tr ≤ Ts, the outdoor unit will operate and the indoor fanoperates in cold air prevention functionIf Tr > Ts+, the outdoor unit turns off and the indoor fan oper-ates at heat residue sending mode.If Tr < Ts+, the outdoor unit will restart and the indoor fanoperates in cold air proof mode.The speed of the indoor fan can be controlled manually bythe user or automatically by the system. The speed can bechanged between HIGH, MEDIUM, and LOW. The predeter-mined conditions for automatic control are as follows:High Speed: Tr < TsMedium Speed: Ts ≤ Tr ≤ Ts + 4°FLow Speed: Tr > Ts + 4°FWhen the indoor fan is running in automatic mode and thereis no delay when the speed switches from high to low, theindoor fan will maintain high speed for a period of 3 minutesbefore switching to low speed.Cold Air Proof OperationAt initial start of heat mode, indoor blower will not be turnedon immediately until indoor coil temperature senses a mini-mum temperature. This period usually takes 30 seconds to 3minutes depending on the outdoor ambient temperature.HSU12 HG(DB)-SM Wiring Diagrams*Indoor fan controlmanual control: You can choose high, medium, low and automatic speed control.Automatic: When Tr |
Related manuals for Haier 1U09AP2VHA
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine