INSTALLATIONPAGE 3ENGLISH2.1 Step 2.1Using a stud sensor, locate and mark the stud positions in thewall where the indoor unit is to be mounted.2.2 Step 2.2Place the mounting plate on the wall in the desired locationtaking into account the minimum clearances necessary forproper operation.Using a level, verify the mounting plate is horizontal and markthe screw locations.2.3 Step 2.3Screw the mounting plate to the wall.The piping for the indoor unit may be routed to the unit fromone of several directions. Left, Left Rear, Right, Right Rear, orBelow (Illustration 1).2.4 Step 2.4Knockouts are provided on the case for Left, Right, and RightBelow.Drilling the hole through the wall for left rear or right rearinstallation2.5 Step 2.5A & 2.5BMeasure and mark the location where the piping hole is to bedrilled.2.6 Step 2.6Drill the piping hole using a hole saw of the correct diameter.Angle the drill with a downward pitch to the outside wall sothat the outside hole will be ¼” lower than the inside hole,giving the hole the proper angle for condensate drainage.2.7 Step 2.7Install the piping hole cover flange at the hole opening on theinside wall.NOTE: The cover flange may require modification to fitproperly behind the wall unit housing.2.8 Step 2.8A & 2.8BBundle the refrigerant piping, drain piping and wiring withtape and pass the bundle through the piping hole.NOTE: When bundling the power cable, leave sufficient lengthavailable in the indoor unit to make the connections to theterminal block.Step 2.1Step 2.3Step 2.2Step 2.4Step 2.5BStep 2.7Step 2.8BStep 2.5AStep 2.6Step 2.8AIllustration 1Piping Exit OptionsRear leftLeft RearrightRightBelowStep 2 - Installation of the Indoor UnitAttaching the Mounting Plate to the Wall