44 HARDI® COMMANDER OPERATOR’S MANUAL3. In-Line filterUnscrew the filter bowl to inspect andclean the filter.Alternative filters are available. Seesection on Technical specifications -Filters and nozzles.4. Spraying circuitFill with clean water, operate all functions and check forleaks using higher spray pressure than normal. Checknozzle spray patterns visually using clean water.5. Retighten bolts (suspension only)Check that these 9 bolts - on each side of the COM-MANDER Plus - are tight. Retighten if necessary.Tightening torque:Bolt 1 = 18 Ft/lb (24 Nm) (secure nut on the backside ofthe mounting with a wrenchwhile adjusting bolt 1).Bolt 2-9: 207 Ft/lb (280 Nm)Bolt 8 and 9 are situated behind the spring.10 hours service1. Suction filterTo service the suction filter:1. Pull out the steel clip A.2. Lift the suction hosefitting B from housing.3. Filter guide and filter Ccan now be removed.To reassemble:4. Press the guide ontofilter end.5. Place the filter intohousing with guidefacing up.6. Ensure the O-ring Don the hose fitting is ingood condition andlubricated.7. Refit the suction hose B and steel clip A.2. Self-Cleaning Filter1. Unscrew nut A and open filter.2. Check filter gauze B, clean ifnecessary3. Lubricate O-ring C4. Assemble filter again.MaintenanceABCD7 6 435 2189* Standard Equipment50 100Suction FilterNozzle Size Self CleaningFilter5030*Red (04)& Larger80*50Lilac (25)Blue (03)Pink (0075)Orange (01)Green (015)Yellow (02)FILTER SIZE SELECTION TABLEInlineFilter1008050*