Chapter 4 Device Configuring Using the Front Panel Configuring the GbE Ports, Sockets and Routing Table© 2012 Harmonic Inc. 50 ProView 7000 v.2.6, Rev. E4.4 Configuring the GbE Ports, Sockets and Routing TableUse the GbE menu to configure the GbE ports, MPE PID, sockets and routing table.To access the GbE menu:❖ Navigate Root > GbE.The GbE menu has the following sub-menus:■ GbE Port 1/2 – Use these menus to configure the following:❑ IP Configuration – Use this menu to configure the following:• IP Address – The default is 127.127.0.X (X is the port number). Each port must have aunique IP address.• Subnet Mask – The default is 255.255.255.0.• Gateway – Output only. The default is 127.127.0.1.❑ MAC Address – Use this menu to view the MAC address for this port.❑ Admin Status – Use this menu to view or set the Admin Status to one of the following:• Up – Enable• Down – DisableIf Admin Status is set to Up and no link is detected, a no link alarm is raised. The defaultis Down.❑ Auto Negotiation – Use this menu to view the Auto Negotiation status or set it to one ofthe following:• On• OffThe default is On.❑ PHY Speed – Use this menu to view the PHY speed. When Auto Negotiation is off you canchange PHY Speed to one of the following:• 100• 1000The default is 1000.❑ Duplex Mode – Only Full Duplex Mode is supported.■ MPE 13 – Use the MPE menu to configure one MPE PID source for GbE out. There are threeservice selection modes, Program, PID and Disabled.The MPE menu comprises the following sub-menus:❑ Mode:• Program – Use this mode to configure an MPE PID by entering the program ID. The PIDis configured automatically.• PID – Use this mode to configure an MPE PID by entering the PID.• Disabled❑ Input Port – Use this menu to select the multiplex input.❑ Program Number – This menu only displays in Program mode.13. Requires a license.